A comparative study of different types of controllers used for blood glucose regulation system

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

Maintaining the glucose concentration in normoglycemic range in Type I diabetic patients is challenging. In this study Hco control is applied for the insulin delivery to prevent the hyperglycaemic levels in a type I diabetic patient. A nonlinear model is linearized around nominal condition and reduced for control synthesis. HOT controller was compared with the two other types of controller and performance results shows evaluatory results.

Original languageEnglish
Pages (from-to)812-817
Number of pages6
JournalCanadian Journal of Chemical Engineering
Volume87
Issue number5
DOIs
Publication statusPublished - 10-2009

Fingerprint

Glucose
Blood Glucose
Blood
Controllers
Insulin

All Science Journal Classification (ASJC) codes

  • Chemical Engineering(all)

Cite this

@article{cc13e4e20b054729bb0e6a7eb6bf0e1a,
title = "A comparative study of different types of controllers used for blood glucose regulation system",
abstract = "Maintaining the glucose concentration in normoglycemic range in Type I diabetic patients is challenging. In this study Hco control is applied for the insulin delivery to prevent the hyperglycaemic levels in a type I diabetic patient. A nonlinear model is linearized around nominal condition and reduced for control synthesis. HOT controller was compared with the two other types of controller and performance results shows evaluatory results.",
author = "Surekha Kamath and George, {V. I.} and Sudha Vidyasagar",
year = "2009",
month = "10",
doi = "10.1002/cjce.20219",
language = "English",
volume = "87",
pages = "812--817",
journal = "Canadian Journal of Chemical Engineering",
issn = "0008-4034",
publisher = "Wiley-Liss Inc.",
number = "5",

}

TY - JOUR

T1 - A comparative study of different types of controllers used for blood glucose regulation system

AU - Kamath, Surekha

AU - George, V. I.

AU - Vidyasagar, Sudha

PY - 2009/10

Y1 - 2009/10

N2 - Maintaining the glucose concentration in normoglycemic range in Type I diabetic patients is challenging. In this study Hco control is applied for the insulin delivery to prevent the hyperglycaemic levels in a type I diabetic patient. A nonlinear model is linearized around nominal condition and reduced for control synthesis. HOT controller was compared with the two other types of controller and performance results shows evaluatory results.

AB - Maintaining the glucose concentration in normoglycemic range in Type I diabetic patients is challenging. In this study Hco control is applied for the insulin delivery to prevent the hyperglycaemic levels in a type I diabetic patient. A nonlinear model is linearized around nominal condition and reduced for control synthesis. HOT controller was compared with the two other types of controller and performance results shows evaluatory results.

UR - http://www.scopus.com/inward/record.url?scp=70349559890&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=70349559890&partnerID=8YFLogxK

U2 - 10.1002/cjce.20219

DO - 10.1002/cjce.20219

M3 - Article

VL - 87

SP - 812

EP - 817

JO - Canadian Journal of Chemical Engineering

JF - Canadian Journal of Chemical Engineering

SN - 0008-4034

IS - 5