A preliminary attempt to profile tympanometric measures in infants using high frequency probe tones

Krishna Yerraguntla, Ramanjeet Kaur, Rohit Ravi

Research output: Contribution to journalArticle

Abstract

There is dearth of published data on high frequency tympanometric measures for infants in Indian context. Aim of present study was to profile Peak compensated static acoustic admittance (Ytm), Tympanometric peak pressure (TPP), Tympanometric width (TW) and Equivalent ear canal volume (Vea) in infants. Cross-sectional study on 50 infants with present TEOAEs and with risk indicators for hearing loss. Tympanometry was performed using GSI-Tympstar for 678 and 1000 Hz probe tones. Descriptive statistics were used to determine mean, SD and minimum and maximum for both genders. Using 678 Hz, Ytm ranged from 0.09 to 1. 48 mmho (males) and 0.11 to 1.14 mmho (females), while with 1000 Hz ranged from 0.15 to 1.49 (males) and 0.13-1.61 mmho (females). Using 678 Hz, TPP ranged from-95 to 70 daPa (males) and-155 to 80 daPa (females), while with 1000 Hz ranged from-75 to 95 daPa (males) and-145 to 50 daPa (females). Using 678 Hz, TW ranged from 30 to 190 daPa (males) and 40-23 daPa (females), while with 1000 Hz ranged from 60 to 210 daPa (males) and 40-183 daPa (females). Using 678 Hz, Vea ranged from 0.11 to 1.7 mmho (males) and 0.14-2.5 mmho (females), while with 1000 Hz ranged from 0.14 to 2.0 mmho (males) and 0.14-3.6 mmho (males). This study was a preliminary attempt to profile the tympanic measures. Ytm values were lesser or similar to other studies, TPP and Vea values had lower and narrow range, while TW were more than previous studies.

Original languageEnglish
Pages (from-to)188-193
Number of pages6
JournalIndian Journal of Otolaryngology and Head and Neck Surgery
Volume70
Issue number2
DOIs
Publication statusPublished - 21-06-2016

Fingerprint

Pressure
Acoustic Impedance Tests
Ear Canal
Hearing Loss
Acoustics
Cross-Sectional Studies

All Science Journal Classification (ASJC) codes

  • Surgery
  • Otorhinolaryngology

Cite this

@article{511442010a704813957af027124c81b8,
title = "A preliminary attempt to profile tympanometric measures in infants using high frequency probe tones",
abstract = "There is dearth of published data on high frequency tympanometric measures for infants in Indian context. Aim of present study was to profile Peak compensated static acoustic admittance (Ytm), Tympanometric peak pressure (TPP), Tympanometric width (TW) and Equivalent ear canal volume (Vea) in infants. Cross-sectional study on 50 infants with present TEOAEs and with risk indicators for hearing loss. Tympanometry was performed using GSI-Tympstar for 678 and 1000 Hz probe tones. Descriptive statistics were used to determine mean, SD and minimum and maximum for both genders. Using 678 Hz, Ytm ranged from 0.09 to 1. 48 mmho (males) and 0.11 to 1.14 mmho (females), while with 1000 Hz ranged from 0.15 to 1.49 (males) and 0.13-1.61 mmho (females). Using 678 Hz, TPP ranged from-95 to 70 daPa (males) and-155 to 80 daPa (females), while with 1000 Hz ranged from-75 to 95 daPa (males) and-145 to 50 daPa (females). Using 678 Hz, TW ranged from 30 to 190 daPa (males) and 40-23 daPa (females), while with 1000 Hz ranged from 60 to 210 daPa (males) and 40-183 daPa (females). Using 678 Hz, Vea ranged from 0.11 to 1.7 mmho (males) and 0.14-2.5 mmho (females), while with 1000 Hz ranged from 0.14 to 2.0 mmho (males) and 0.14-3.6 mmho (males). This study was a preliminary attempt to profile the tympanic measures. Ytm values were lesser or similar to other studies, TPP and Vea values had lower and narrow range, while TW were more than previous studies.",
author = "Krishna Yerraguntla and Ramanjeet Kaur and Rohit Ravi",
year = "2016",
month = "6",
day = "21",
doi = "10.1007/s12070-016-1004-2",
language = "English",
volume = "70",
pages = "188--193",
journal = "Indian Journal of Otolaryngology and Head and Neck Surgery",
issn = "2231-3796",
publisher = "Springer India",
number = "2",

}

A preliminary attempt to profile tympanometric measures in infants using high frequency probe tones. / Yerraguntla, Krishna; Kaur, Ramanjeet; Ravi, Rohit.

In: Indian Journal of Otolaryngology and Head and Neck Surgery, Vol. 70, No. 2, 21.06.2016, p. 188-193.

Research output: Contribution to journalArticle

TY - JOUR

T1 - A preliminary attempt to profile tympanometric measures in infants using high frequency probe tones

AU - Yerraguntla, Krishna

AU - Kaur, Ramanjeet

AU - Ravi, Rohit

PY - 2016/6/21

Y1 - 2016/6/21

N2 - There is dearth of published data on high frequency tympanometric measures for infants in Indian context. Aim of present study was to profile Peak compensated static acoustic admittance (Ytm), Tympanometric peak pressure (TPP), Tympanometric width (TW) and Equivalent ear canal volume (Vea) in infants. Cross-sectional study on 50 infants with present TEOAEs and with risk indicators for hearing loss. Tympanometry was performed using GSI-Tympstar for 678 and 1000 Hz probe tones. Descriptive statistics were used to determine mean, SD and minimum and maximum for both genders. Using 678 Hz, Ytm ranged from 0.09 to 1. 48 mmho (males) and 0.11 to 1.14 mmho (females), while with 1000 Hz ranged from 0.15 to 1.49 (males) and 0.13-1.61 mmho (females). Using 678 Hz, TPP ranged from-95 to 70 daPa (males) and-155 to 80 daPa (females), while with 1000 Hz ranged from-75 to 95 daPa (males) and-145 to 50 daPa (females). Using 678 Hz, TW ranged from 30 to 190 daPa (males) and 40-23 daPa (females), while with 1000 Hz ranged from 60 to 210 daPa (males) and 40-183 daPa (females). Using 678 Hz, Vea ranged from 0.11 to 1.7 mmho (males) and 0.14-2.5 mmho (females), while with 1000 Hz ranged from 0.14 to 2.0 mmho (males) and 0.14-3.6 mmho (males). This study was a preliminary attempt to profile the tympanic measures. Ytm values were lesser or similar to other studies, TPP and Vea values had lower and narrow range, while TW were more than previous studies.

AB - There is dearth of published data on high frequency tympanometric measures for infants in Indian context. Aim of present study was to profile Peak compensated static acoustic admittance (Ytm), Tympanometric peak pressure (TPP), Tympanometric width (TW) and Equivalent ear canal volume (Vea) in infants. Cross-sectional study on 50 infants with present TEOAEs and with risk indicators for hearing loss. Tympanometry was performed using GSI-Tympstar for 678 and 1000 Hz probe tones. Descriptive statistics were used to determine mean, SD and minimum and maximum for both genders. Using 678 Hz, Ytm ranged from 0.09 to 1. 48 mmho (males) and 0.11 to 1.14 mmho (females), while with 1000 Hz ranged from 0.15 to 1.49 (males) and 0.13-1.61 mmho (females). Using 678 Hz, TPP ranged from-95 to 70 daPa (males) and-155 to 80 daPa (females), while with 1000 Hz ranged from-75 to 95 daPa (males) and-145 to 50 daPa (females). Using 678 Hz, TW ranged from 30 to 190 daPa (males) and 40-23 daPa (females), while with 1000 Hz ranged from 60 to 210 daPa (males) and 40-183 daPa (females). Using 678 Hz, Vea ranged from 0.11 to 1.7 mmho (males) and 0.14-2.5 mmho (females), while with 1000 Hz ranged from 0.14 to 2.0 mmho (males) and 0.14-3.6 mmho (males). This study was a preliminary attempt to profile the tympanic measures. Ytm values were lesser or similar to other studies, TPP and Vea values had lower and narrow range, while TW were more than previous studies.

UR - http://www.scopus.com/inward/record.url?scp=85063667379&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85063667379&partnerID=8YFLogxK

U2 - 10.1007/s12070-016-1004-2

DO - 10.1007/s12070-016-1004-2

M3 - Article

VL - 70

SP - 188

EP - 193

JO - Indian Journal of Otolaryngology and Head and Neck Surgery

JF - Indian Journal of Otolaryngology and Head and Neck Surgery

SN - 2231-3796

IS - 2

ER -