An adaptive calibration circuit for flow measurement using venturi

K. V. Santhosh, B. K. Roy

Research output: Chapter in Book/Report/Conference proceedingConference contribution

1 Citation (Scopus)

Abstract

Design of an adaptive calibration circuit for flow measurement technique using venturi flow meter is reported in this paper. The objectives of the present work are: (i) to extend the linearity range of measurement to 100% of full scale input range, (ii) to make the measurement technique adaptive to variations in discharge coefficient, diameter ratio of venturi nozzle and pipe (β), liquid density, and liquid temperature, and (iii) to achieve the objectives (i) and (ii) using an optimized neural network. A suitable optimized ANN is added, in place of conventional calibration circuit, in cascade to data conversion unit. To produce outputs linear to input flow for the entire input range, and adaptive to variations in discharge coefficient, diameter ratio, liquid density, and temperature. Results show that the proposed technique has fulfilled the objectives.

Original languageEnglish
Title of host publication2013 International Conference on Computer Communication and Informatics, ICCCI 2013
DOIs
Publication statusPublished - 2013
Externally publishedYes
Event2013 3rd International Conference on Computer Communication and Informatics, ICCCI 2013 - Coimbatore, India
Duration: 04-01-201306-01-2013

Conference

Conference2013 3rd International Conference on Computer Communication and Informatics, ICCCI 2013
CountryIndia
CityCoimbatore
Period04-01-1306-01-13

Fingerprint

Density of liquids
Flow measurement
Calibration
Networks (circuits)
Nozzles
Pipe
Neural networks
Temperature
Liquids

All Science Journal Classification (ASJC) codes

  • Computer Networks and Communications
  • Information Systems

Cite this

Santhosh, K. V., & Roy, B. K. (2013). An adaptive calibration circuit for flow measurement using venturi. In 2013 International Conference on Computer Communication and Informatics, ICCCI 2013 [6466261] https://doi.org/10.1109/ICCCI.2013.6466261
Santhosh, K. V. ; Roy, B. K. / An adaptive calibration circuit for flow measurement using venturi. 2013 International Conference on Computer Communication and Informatics, ICCCI 2013. 2013.
@inproceedings{494e79a5c8b6422291a1a7eb3fb8e4e9,
title = "An adaptive calibration circuit for flow measurement using venturi",
abstract = "Design of an adaptive calibration circuit for flow measurement technique using venturi flow meter is reported in this paper. The objectives of the present work are: (i) to extend the linearity range of measurement to 100{\%} of full scale input range, (ii) to make the measurement technique adaptive to variations in discharge coefficient, diameter ratio of venturi nozzle and pipe (β), liquid density, and liquid temperature, and (iii) to achieve the objectives (i) and (ii) using an optimized neural network. A suitable optimized ANN is added, in place of conventional calibration circuit, in cascade to data conversion unit. To produce outputs linear to input flow for the entire input range, and adaptive to variations in discharge coefficient, diameter ratio, liquid density, and temperature. Results show that the proposed technique has fulfilled the objectives.",
author = "Santhosh, {K. V.} and Roy, {B. K.}",
year = "2013",
doi = "10.1109/ICCCI.2013.6466261",
language = "English",
isbn = "9781467329057",
booktitle = "2013 International Conference on Computer Communication and Informatics, ICCCI 2013",

}

Santhosh, KV & Roy, BK 2013, An adaptive calibration circuit for flow measurement using venturi. in 2013 International Conference on Computer Communication and Informatics, ICCCI 2013., 6466261, 2013 3rd International Conference on Computer Communication and Informatics, ICCCI 2013, Coimbatore, India, 04-01-13. https://doi.org/10.1109/ICCCI.2013.6466261

An adaptive calibration circuit for flow measurement using venturi. / Santhosh, K. V.; Roy, B. K.

2013 International Conference on Computer Communication and Informatics, ICCCI 2013. 2013. 6466261.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

TY - GEN

T1 - An adaptive calibration circuit for flow measurement using venturi

AU - Santhosh, K. V.

AU - Roy, B. K.

PY - 2013

Y1 - 2013

N2 - Design of an adaptive calibration circuit for flow measurement technique using venturi flow meter is reported in this paper. The objectives of the present work are: (i) to extend the linearity range of measurement to 100% of full scale input range, (ii) to make the measurement technique adaptive to variations in discharge coefficient, diameter ratio of venturi nozzle and pipe (β), liquid density, and liquid temperature, and (iii) to achieve the objectives (i) and (ii) using an optimized neural network. A suitable optimized ANN is added, in place of conventional calibration circuit, in cascade to data conversion unit. To produce outputs linear to input flow for the entire input range, and adaptive to variations in discharge coefficient, diameter ratio, liquid density, and temperature. Results show that the proposed technique has fulfilled the objectives.

AB - Design of an adaptive calibration circuit for flow measurement technique using venturi flow meter is reported in this paper. The objectives of the present work are: (i) to extend the linearity range of measurement to 100% of full scale input range, (ii) to make the measurement technique adaptive to variations in discharge coefficient, diameter ratio of venturi nozzle and pipe (β), liquid density, and liquid temperature, and (iii) to achieve the objectives (i) and (ii) using an optimized neural network. A suitable optimized ANN is added, in place of conventional calibration circuit, in cascade to data conversion unit. To produce outputs linear to input flow for the entire input range, and adaptive to variations in discharge coefficient, diameter ratio, liquid density, and temperature. Results show that the proposed technique has fulfilled the objectives.

UR - http://www.scopus.com/inward/record.url?scp=84874686512&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84874686512&partnerID=8YFLogxK

U2 - 10.1109/ICCCI.2013.6466261

DO - 10.1109/ICCCI.2013.6466261

M3 - Conference contribution

AN - SCOPUS:84874686512

SN - 9781467329057

BT - 2013 International Conference on Computer Communication and Informatics, ICCCI 2013

ER -

Santhosh KV, Roy BK. An adaptive calibration circuit for flow measurement using venturi. In 2013 International Conference on Computer Communication and Informatics, ICCCI 2013. 2013. 6466261 https://doi.org/10.1109/ICCCI.2013.6466261