In restructured power systems, load following is considered to be one among the many ancillary services necessary to support the transmission of electric power. This paper investigates the performance of a load following controller on each generator involved in bilateral contracts. A suitable control strategy is also proposed for the generators taking part in load following to share a portion of the uncontracted power demanded by the customers. Simulation studies carried out on a two-area interconnected power system show that the proposed control schemes are very effective for the generators taking part in load following.

Original languageEnglish
Title of host publicationProceedings of 2009 7th Asian Control Conference, ASCC 2009
Pages1199-1204
Number of pages6
Publication statusPublished - 11-12-2009
Externally publishedYes
Event2009 7th Asian Control Conference, ASCC 2009 - Hong Kong, China
Duration: 27-08-200929-08-2009

Conference

Conference2009 7th Asian Control Conference, ASCC 2009
CountryChina
CityHong Kong
Period27-08-0929-08-09

Fingerprint

Electric power system interconnection
Controllers

All Science Journal Classification (ASJC) codes

  • Computational Theory and Mathematics
  • Computer Vision and Pattern Recognition
  • Control and Systems Engineering

Cite this

Abraham, R. J., Das, D., & Patra, A. (2009). Bilateral load following in a restructured power system with local controllers. In Proceedings of 2009 7th Asian Control Conference, ASCC 2009 (pp. 1199-1204). [5276325]
Abraham, Rajesh Joseph ; Das, D. ; Patra, Amit. / Bilateral load following in a restructured power system with local controllers. Proceedings of 2009 7th Asian Control Conference, ASCC 2009. 2009. pp. 1199-1204
@inproceedings{1e488516d33b4570be27062a7844faf1,
title = "Bilateral load following in a restructured power system with local controllers",
abstract = "In restructured power systems, load following is considered to be one among the many ancillary services necessary to support the transmission of electric power. This paper investigates the performance of a load following controller on each generator involved in bilateral contracts. A suitable control strategy is also proposed for the generators taking part in load following to share a portion of the uncontracted power demanded by the customers. Simulation studies carried out on a two-area interconnected power system show that the proposed control schemes are very effective for the generators taking part in load following.",
author = "Abraham, {Rajesh Joseph} and D. Das and Amit Patra",
year = "2009",
month = "12",
day = "11",
language = "English",
isbn = "9788995605691",
pages = "1199--1204",
booktitle = "Proceedings of 2009 7th Asian Control Conference, ASCC 2009",

}

Abraham, RJ, Das, D & Patra, A 2009, Bilateral load following in a restructured power system with local controllers. in Proceedings of 2009 7th Asian Control Conference, ASCC 2009., 5276325, pp. 1199-1204, 2009 7th Asian Control Conference, ASCC 2009, Hong Kong, China, 27-08-09.

Bilateral load following in a restructured power system with local controllers. / Abraham, Rajesh Joseph; Das, D.; Patra, Amit.

Proceedings of 2009 7th Asian Control Conference, ASCC 2009. 2009. p. 1199-1204 5276325.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

TY - GEN

T1 - Bilateral load following in a restructured power system with local controllers

AU - Abraham, Rajesh Joseph

AU - Das, D.

AU - Patra, Amit

PY - 2009/12/11

Y1 - 2009/12/11

N2 - In restructured power systems, load following is considered to be one among the many ancillary services necessary to support the transmission of electric power. This paper investigates the performance of a load following controller on each generator involved in bilateral contracts. A suitable control strategy is also proposed for the generators taking part in load following to share a portion of the uncontracted power demanded by the customers. Simulation studies carried out on a two-area interconnected power system show that the proposed control schemes are very effective for the generators taking part in load following.

AB - In restructured power systems, load following is considered to be one among the many ancillary services necessary to support the transmission of electric power. This paper investigates the performance of a load following controller on each generator involved in bilateral contracts. A suitable control strategy is also proposed for the generators taking part in load following to share a portion of the uncontracted power demanded by the customers. Simulation studies carried out on a two-area interconnected power system show that the proposed control schemes are very effective for the generators taking part in load following.

UR - http://www.scopus.com/inward/record.url?scp=71449109576&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=71449109576&partnerID=8YFLogxK

M3 - Conference contribution

SN - 9788995605691

SP - 1199

EP - 1204

BT - Proceedings of 2009 7th Asian Control Conference, ASCC 2009

ER -

Abraham RJ, Das D, Patra A. Bilateral load following in a restructured power system with local controllers. In Proceedings of 2009 7th Asian Control Conference, ASCC 2009. 2009. p. 1199-1204. 5276325