TY - JOUR
T1 - Bioanalytical chiral chromatographic technique and docking studies for enantioselective separation of meclizine hydrochloride
T2 - Application to pharmacokinetic study in rabbits
AU - Raikar, Prachi
AU - Gurupadayya, Bannimath
AU - Mandal, Subhankar P.
AU - Narhari, Rishitha
AU - Subramanyam, Sripuram
AU - Srinivasu, Gunnam
AU - Rajan, Surulivel
AU - Saikumar, Matcha
AU - Koganti, Sairam
PY - 2020/8/1
Y1 - 2020/8/1
N2 - Enantiomeric resolution and molecular docking studies of meclizine hydrochloride on polysaccharide-based chiral stationary phase comprising cellulose tris(4-methylbenzoate) chiral selector (150 × 4.6 mm, 3.0 μm) were presented. The mobile phase used was acetonitrile:10mM ammonium bicarbonate (95:05, v/v). The developed technique was used to perform the enantioselective assay of meclizine hydrochloride in its marketed formulation. The elution order of meclizine hydrochloride enantiomers was determined by docking studies. Target compound was extracted from rabbit plasma using protein precipitation technique, followed by development of bioanalytical chiral separation method using the same matrix. Application of the method to determine pharmacokinetic parameters of meclizine hydrochloride enantiomers was performed using Phoenix WinNonlin 8.1 software. The results demonstrated stereoselective disposition of meclizine hydrochloride enantiomers in rabbits.
AB - Enantiomeric resolution and molecular docking studies of meclizine hydrochloride on polysaccharide-based chiral stationary phase comprising cellulose tris(4-methylbenzoate) chiral selector (150 × 4.6 mm, 3.0 μm) were presented. The mobile phase used was acetonitrile:10mM ammonium bicarbonate (95:05, v/v). The developed technique was used to perform the enantioselective assay of meclizine hydrochloride in its marketed formulation. The elution order of meclizine hydrochloride enantiomers was determined by docking studies. Target compound was extracted from rabbit plasma using protein precipitation technique, followed by development of bioanalytical chiral separation method using the same matrix. Application of the method to determine pharmacokinetic parameters of meclizine hydrochloride enantiomers was performed using Phoenix WinNonlin 8.1 software. The results demonstrated stereoselective disposition of meclizine hydrochloride enantiomers in rabbits.
UR - http://www.scopus.com/inward/record.url?scp=85087213062&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85087213062&partnerID=8YFLogxK
U2 - 10.1002/chir.23241
DO - 10.1002/chir.23241
M3 - Article
C2 - 32567097
AN - SCOPUS:85087213062
SN - 0899-0042
JO - Chirality
JF - Chirality
ER -