Stainless steel band material was developed and tested for physico-chemical mechanical toxicological and in-vitro evaluation in dogs, at the Sree Chitra Thirunal Medical Institute, Trivandrum. Weld strength and tensile strength were measured with the Instron testing machine. A clinical pilot study was conducted at College of Dental Surgery, Manipal on 150 patients earlier. In the present study, Chitra bands were cemented on upper and lower molars on one side and Dentaurum bands on the other side, as controls in the same patient. The band was allocated to right and left molars at random. The study was a double blind trial. Thus fifty cases had Chitra bands on the left side and fifty on the tight side. Hundred cases were treated with fixed appliance treatment. The age, sex and technique of treatment were recorded. The spot welder and the cement used were also noted. The patients were recalled every month for nine months and the findings entered in the initial and follow-up proforma by another Orthodontist, making it a blind study. Loose bands, broken bands, broken tubes, broken welds, plaque accumulation, gingival bleeding and gingivitis were noted. The findings will be presented and the clinical applicability of Chitra Band Material discussed.

Original languageEnglish
Pages (from-to)99-104
Number of pages6
JournalBiomedical Sciences Instrumentation
Volume36
Publication statusPublished - 15-05-2000
Externally publishedYes

Fingerprint

Clinical Trials
Gingivitis
Tensile Strength
Stainless Steel
Toxicology
Tooth
Dogs
Hemorrhage
Chitra
Therapeutics
In Vitro Techniques
Orthodontists
Clinical Studies

All Science Journal Classification (ASJC) codes

  • Biophysics
  • Medical Laboratory Technology

Cite this

Valiathan, A., Shah, B., & Prabhakar, A. K. (2000). Clinical trials of Chitra Band Material. Biomedical Sciences Instrumentation, 36, 99-104.
Valiathan, Ashima ; Shah, Bela ; Prabhakar, A. K. / Clinical trials of Chitra Band Material. In: Biomedical Sciences Instrumentation. 2000 ; Vol. 36. pp. 99-104.
@article{b386c21cb50e4df3a5ff39cabc400ade,
title = "Clinical trials of Chitra Band Material",
abstract = "Stainless steel band material was developed and tested for physico-chemical mechanical toxicological and in-vitro evaluation in dogs, at the Sree Chitra Thirunal Medical Institute, Trivandrum. Weld strength and tensile strength were measured with the Instron testing machine. A clinical pilot study was conducted at College of Dental Surgery, Manipal on 150 patients earlier. In the present study, Chitra bands were cemented on upper and lower molars on one side and Dentaurum bands on the other side, as controls in the same patient. The band was allocated to right and left molars at random. The study was a double blind trial. Thus fifty cases had Chitra bands on the left side and fifty on the tight side. Hundred cases were treated with fixed appliance treatment. The age, sex and technique of treatment were recorded. The spot welder and the cement used were also noted. The patients were recalled every month for nine months and the findings entered in the initial and follow-up proforma by another Orthodontist, making it a blind study. Loose bands, broken bands, broken tubes, broken welds, plaque accumulation, gingival bleeding and gingivitis were noted. The findings will be presented and the clinical applicability of Chitra Band Material discussed.",
author = "Ashima Valiathan and Bela Shah and Prabhakar, {A. K.}",
year = "2000",
month = "5",
day = "15",
language = "English",
volume = "36",
pages = "99--104",
journal = "Biomedical Sciences Instrumentation",
issn = "0067-8856",
publisher = "ISA - Instrumentation, Systems, and Automation Society",

}

Valiathan, A, Shah, B & Prabhakar, AK 2000, 'Clinical trials of Chitra Band Material', Biomedical Sciences Instrumentation, vol. 36, pp. 99-104.

Clinical trials of Chitra Band Material. / Valiathan, Ashima; Shah, Bela; Prabhakar, A. K.

In: Biomedical Sciences Instrumentation, Vol. 36, 15.05.2000, p. 99-104.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Clinical trials of Chitra Band Material

AU - Valiathan, Ashima

AU - Shah, Bela

AU - Prabhakar, A. K.

PY - 2000/5/15

Y1 - 2000/5/15

N2 - Stainless steel band material was developed and tested for physico-chemical mechanical toxicological and in-vitro evaluation in dogs, at the Sree Chitra Thirunal Medical Institute, Trivandrum. Weld strength and tensile strength were measured with the Instron testing machine. A clinical pilot study was conducted at College of Dental Surgery, Manipal on 150 patients earlier. In the present study, Chitra bands were cemented on upper and lower molars on one side and Dentaurum bands on the other side, as controls in the same patient. The band was allocated to right and left molars at random. The study was a double blind trial. Thus fifty cases had Chitra bands on the left side and fifty on the tight side. Hundred cases were treated with fixed appliance treatment. The age, sex and technique of treatment were recorded. The spot welder and the cement used were also noted. The patients were recalled every month for nine months and the findings entered in the initial and follow-up proforma by another Orthodontist, making it a blind study. Loose bands, broken bands, broken tubes, broken welds, plaque accumulation, gingival bleeding and gingivitis were noted. The findings will be presented and the clinical applicability of Chitra Band Material discussed.

AB - Stainless steel band material was developed and tested for physico-chemical mechanical toxicological and in-vitro evaluation in dogs, at the Sree Chitra Thirunal Medical Institute, Trivandrum. Weld strength and tensile strength were measured with the Instron testing machine. A clinical pilot study was conducted at College of Dental Surgery, Manipal on 150 patients earlier. In the present study, Chitra bands were cemented on upper and lower molars on one side and Dentaurum bands on the other side, as controls in the same patient. The band was allocated to right and left molars at random. The study was a double blind trial. Thus fifty cases had Chitra bands on the left side and fifty on the tight side. Hundred cases were treated with fixed appliance treatment. The age, sex and technique of treatment were recorded. The spot welder and the cement used were also noted. The patients were recalled every month for nine months and the findings entered in the initial and follow-up proforma by another Orthodontist, making it a blind study. Loose bands, broken bands, broken tubes, broken welds, plaque accumulation, gingival bleeding and gingivitis were noted. The findings will be presented and the clinical applicability of Chitra Band Material discussed.

UR - http://www.scopus.com/inward/record.url?scp=0034093342&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0034093342&partnerID=8YFLogxK

M3 - Article

VL - 36

SP - 99

EP - 104

JO - Biomedical Sciences Instrumentation

JF - Biomedical Sciences Instrumentation

SN - 0067-8856

ER -

Valiathan A, Shah B, Prabhakar AK. Clinical trials of Chitra Band Material. Biomedical Sciences Instrumentation. 2000 May 15;36:99-104.