Combined Natural Convection and Surface Radiation Inside Vented Triangular Enclosure - An Experimental Study

Rahul Raj, K. C. Pradyumna, B. R. Rakshith, R. B. Nithin, S. R. Karthik

Research output: Contribution to journalConference article

Abstract

In the present experimental study, the influence of Opening ratio on the chamber temperature in case of vented triangular enclosure with hot base plate has been undertaken. Due to more flow passage, the average air temperature in the enclosure decreases by 12% for OR of 0.25 and 13% for OR of 0.5 compared to OR of 0.125. Similar trend is observed for Rayleigh number with a rise of 73% in OR 0.5 compared to OR of 0.125. Further, the influence of radiation heat transfer in the natural convection based enclosure is also studied. This kind of investigation is useful in the design and analysis of electronic cooling systems.

Original languageEnglish
Article number04019
JournalMATEC Web of Conferences
Volume144
DOIs
Publication statusPublished - 09-01-2018
Externally publishedYes

Fingerprint

Enclosures
Natural convection
Radiation
Electronic cooling
Heat radiation
Cooling systems
Temperature
Air

All Science Journal Classification (ASJC) codes

  • Chemistry(all)
  • Materials Science(all)
  • Engineering(all)

Cite this

Raj, Rahul ; Pradyumna, K. C. ; Rakshith, B. R. ; Nithin, R. B. ; Karthik, S. R. / Combined Natural Convection and Surface Radiation Inside Vented Triangular Enclosure - An Experimental Study. In: MATEC Web of Conferences. 2018 ; Vol. 144.
@article{55a30d8fd6584b42ab63ba7f4b5fb8c1,
title = "Combined Natural Convection and Surface Radiation Inside Vented Triangular Enclosure - An Experimental Study",
abstract = "In the present experimental study, the influence of Opening ratio on the chamber temperature in case of vented triangular enclosure with hot base plate has been undertaken. Due to more flow passage, the average air temperature in the enclosure decreases by 12{\%} for OR of 0.25 and 13{\%} for OR of 0.5 compared to OR of 0.125. Similar trend is observed for Rayleigh number with a rise of 73{\%} in OR 0.5 compared to OR of 0.125. Further, the influence of radiation heat transfer in the natural convection based enclosure is also studied. This kind of investigation is useful in the design and analysis of electronic cooling systems.",
author = "Rahul Raj and Pradyumna, {K. C.} and Rakshith, {B. R.} and Nithin, {R. B.} and Karthik, {S. R.}",
year = "2018",
month = "1",
day = "9",
doi = "10.1051/matecconf/201714404019",
language = "English",
volume = "144",
journal = "MATEC Web of Conferences",
issn = "2261-236X",
publisher = "EDP Sciences",

}

Combined Natural Convection and Surface Radiation Inside Vented Triangular Enclosure - An Experimental Study. / Raj, Rahul; Pradyumna, K. C.; Rakshith, B. R.; Nithin, R. B.; Karthik, S. R.

In: MATEC Web of Conferences, Vol. 144, 04019, 09.01.2018.

Research output: Contribution to journalConference article

TY - JOUR

T1 - Combined Natural Convection and Surface Radiation Inside Vented Triangular Enclosure - An Experimental Study

AU - Raj, Rahul

AU - Pradyumna, K. C.

AU - Rakshith, B. R.

AU - Nithin, R. B.

AU - Karthik, S. R.

PY - 2018/1/9

Y1 - 2018/1/9

N2 - In the present experimental study, the influence of Opening ratio on the chamber temperature in case of vented triangular enclosure with hot base plate has been undertaken. Due to more flow passage, the average air temperature in the enclosure decreases by 12% for OR of 0.25 and 13% for OR of 0.5 compared to OR of 0.125. Similar trend is observed for Rayleigh number with a rise of 73% in OR 0.5 compared to OR of 0.125. Further, the influence of radiation heat transfer in the natural convection based enclosure is also studied. This kind of investigation is useful in the design and analysis of electronic cooling systems.

AB - In the present experimental study, the influence of Opening ratio on the chamber temperature in case of vented triangular enclosure with hot base plate has been undertaken. Due to more flow passage, the average air temperature in the enclosure decreases by 12% for OR of 0.25 and 13% for OR of 0.5 compared to OR of 0.125. Similar trend is observed for Rayleigh number with a rise of 73% in OR 0.5 compared to OR of 0.125. Further, the influence of radiation heat transfer in the natural convection based enclosure is also studied. This kind of investigation is useful in the design and analysis of electronic cooling systems.

UR - http://www.scopus.com/inward/record.url?scp=85040686173&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85040686173&partnerID=8YFLogxK

U2 - 10.1051/matecconf/201714404019

DO - 10.1051/matecconf/201714404019

M3 - Conference article

VL - 144

JO - MATEC Web of Conferences

JF - MATEC Web of Conferences

SN - 2261-236X

M1 - 04019

ER -