Comparison of accuracy of partial coherence interferometry based zeiss IOL master 500 and immersion ultrasound (Ocuscan RXP) for intraocular lens power calculation

H. Vijaya Pai, Divya Shastri, Asha Kamath

Research output: Contribution to journalArticle

Abstract

Aim: To compare accuracy of intraocular lens power (IOL) calculation using Partial coherence Interferometry based Carl Zeiss IOL master 500 and Immersion ultrasound (Alcon Ocuscan RXP). Methods: A prospective randomized study of patients who underwent clear corneal phacoemulsification with foldable (IOL) by a single surgeon, during the period September 2010 to 2012. Group A included those patients in whom IOL power calculation using Immersion ultrasound (Ocuscan RXP) was used. Group B included those patients in whom IOL power calculation using Partial coherence Interferometry based Zeiss IOL master was used. SRK T formula was used to calculate the IOL power in both the groups. Postoperative final refraction was done at 6 weeks. Unaided visual acuity and best corrected visual acuity was assessed. Postoperative refractive error was compared with predicted refractive error with each biometry method. Statistical analysis was done using SPSS 16.5. Continuous variables expressed as mean (standard deviation). P < 0.05 was considered significant. Results: There were 50 patients in Group A, 44 patients in Group B. Axial length of the patients varied from 22-26mm in both the groups. The postoperative refraction using Ocuscan, 88% had refractive error ≤± 0.5 D, 94% had ≤±1.00D, and 100% had ≤±2.0D of emmetropia. Using Zeiss IOL Master 72.7% had ≤± 0.5 D, 100% had ≤±1.00D of refractive error. Difference in absolute postoperative refractive error using Ocuscan vs. IOL Master was not statistically significant. Conclusion: In our study both ultrasound Ocuscan and IOL master were accurate in calculating intraocular lens power and achieving postoperative refraction closer to emmetropia.

Original languageEnglish
Pages (from-to)185-191
Number of pages7
JournalAsian Journal of Ophthalmology
Volume14
Issue number4
Publication statusPublished - 2016

Fingerprint

Interferometry
Intraocular Lenses
Immersion
Refractive Errors
Emmetropia
Power (Psychology)
Visual Acuity
Biometry
Phacoemulsification

All Science Journal Classification (ASJC) codes

  • Ophthalmology

Cite this

@article{857fc471107748f98b0920b86dbe1b5d,
title = "Comparison of accuracy of partial coherence interferometry based zeiss IOL master 500 and immersion ultrasound (Ocuscan RXP) for intraocular lens power calculation",
abstract = "Aim: To compare accuracy of intraocular lens power (IOL) calculation using Partial coherence Interferometry based Carl Zeiss IOL master 500 and Immersion ultrasound (Alcon Ocuscan RXP). Methods: A prospective randomized study of patients who underwent clear corneal phacoemulsification with foldable (IOL) by a single surgeon, during the period September 2010 to 2012. Group A included those patients in whom IOL power calculation using Immersion ultrasound (Ocuscan RXP) was used. Group B included those patients in whom IOL power calculation using Partial coherence Interferometry based Zeiss IOL master was used. SRK T formula was used to calculate the IOL power in both the groups. Postoperative final refraction was done at 6 weeks. Unaided visual acuity and best corrected visual acuity was assessed. Postoperative refractive error was compared with predicted refractive error with each biometry method. Statistical analysis was done using SPSS 16.5. Continuous variables expressed as mean (standard deviation). P < 0.05 was considered significant. Results: There were 50 patients in Group A, 44 patients in Group B. Axial length of the patients varied from 22-26mm in both the groups. The postoperative refraction using Ocuscan, 88{\%} had refractive error ≤± 0.5 D, 94{\%} had ≤±1.00D, and 100{\%} had ≤±2.0D of emmetropia. Using Zeiss IOL Master 72.7{\%} had ≤± 0.5 D, 100{\%} had ≤±1.00D of refractive error. Difference in absolute postoperative refractive error using Ocuscan vs. IOL Master was not statistically significant. Conclusion: In our study both ultrasound Ocuscan and IOL master were accurate in calculating intraocular lens power and achieving postoperative refraction closer to emmetropia.",
author = "{Vijaya Pai}, H. and Divya Shastri and Asha Kamath",
year = "2016",
language = "English",
volume = "14",
pages = "185--191",
journal = "Asian Journal of Ophthalmology",
issn = "1560-2133",
publisher = "Scientific Communications International Ltd.",
number = "4",

}

TY - JOUR

T1 - Comparison of accuracy of partial coherence interferometry based zeiss IOL master 500 and immersion ultrasound (Ocuscan RXP) for intraocular lens power calculation

AU - Vijaya Pai, H.

AU - Shastri, Divya

AU - Kamath, Asha

PY - 2016

Y1 - 2016

N2 - Aim: To compare accuracy of intraocular lens power (IOL) calculation using Partial coherence Interferometry based Carl Zeiss IOL master 500 and Immersion ultrasound (Alcon Ocuscan RXP). Methods: A prospective randomized study of patients who underwent clear corneal phacoemulsification with foldable (IOL) by a single surgeon, during the period September 2010 to 2012. Group A included those patients in whom IOL power calculation using Immersion ultrasound (Ocuscan RXP) was used. Group B included those patients in whom IOL power calculation using Partial coherence Interferometry based Zeiss IOL master was used. SRK T formula was used to calculate the IOL power in both the groups. Postoperative final refraction was done at 6 weeks. Unaided visual acuity and best corrected visual acuity was assessed. Postoperative refractive error was compared with predicted refractive error with each biometry method. Statistical analysis was done using SPSS 16.5. Continuous variables expressed as mean (standard deviation). P < 0.05 was considered significant. Results: There were 50 patients in Group A, 44 patients in Group B. Axial length of the patients varied from 22-26mm in both the groups. The postoperative refraction using Ocuscan, 88% had refractive error ≤± 0.5 D, 94% had ≤±1.00D, and 100% had ≤±2.0D of emmetropia. Using Zeiss IOL Master 72.7% had ≤± 0.5 D, 100% had ≤±1.00D of refractive error. Difference in absolute postoperative refractive error using Ocuscan vs. IOL Master was not statistically significant. Conclusion: In our study both ultrasound Ocuscan and IOL master were accurate in calculating intraocular lens power and achieving postoperative refraction closer to emmetropia.

AB - Aim: To compare accuracy of intraocular lens power (IOL) calculation using Partial coherence Interferometry based Carl Zeiss IOL master 500 and Immersion ultrasound (Alcon Ocuscan RXP). Methods: A prospective randomized study of patients who underwent clear corneal phacoemulsification with foldable (IOL) by a single surgeon, during the period September 2010 to 2012. Group A included those patients in whom IOL power calculation using Immersion ultrasound (Ocuscan RXP) was used. Group B included those patients in whom IOL power calculation using Partial coherence Interferometry based Zeiss IOL master was used. SRK T formula was used to calculate the IOL power in both the groups. Postoperative final refraction was done at 6 weeks. Unaided visual acuity and best corrected visual acuity was assessed. Postoperative refractive error was compared with predicted refractive error with each biometry method. Statistical analysis was done using SPSS 16.5. Continuous variables expressed as mean (standard deviation). P < 0.05 was considered significant. Results: There were 50 patients in Group A, 44 patients in Group B. Axial length of the patients varied from 22-26mm in both the groups. The postoperative refraction using Ocuscan, 88% had refractive error ≤± 0.5 D, 94% had ≤±1.00D, and 100% had ≤±2.0D of emmetropia. Using Zeiss IOL Master 72.7% had ≤± 0.5 D, 100% had ≤±1.00D of refractive error. Difference in absolute postoperative refractive error using Ocuscan vs. IOL Master was not statistically significant. Conclusion: In our study both ultrasound Ocuscan and IOL master were accurate in calculating intraocular lens power and achieving postoperative refraction closer to emmetropia.

UR - http://www.scopus.com/inward/record.url?scp=84959367492&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84959367492&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:84959367492

VL - 14

SP - 185

EP - 191

JO - Asian Journal of Ophthalmology

JF - Asian Journal of Ophthalmology

SN - 1560-2133

IS - 4