Comparison of flow in normal and stenosed carotid bulb

S. M Abdul Khader, B. Raghuvir Pai, Anurag Ayachit, V. R K Rao, S. Ganesh Kamath

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

Computational Fluid Dynamics (CFD) is one of the growing challenges in scientific computing wherein the complex fluid domains are analyzed. One such domain is blood flow analysis through elastic arteries. Such an analysis can be a promising future for the medical field where realistic physiological conditions can be simulated to observe the flow behavior. In the present study, a case study of normal and stenosed carotid bifurcation is simulated for a Newtonian case. The models are generated in CATIA based on the clinical data obtained from Ultrasound Doppler from a patient. A transient CFD analysis is performed for several pulse cycles for normal and stenosed models using ANSYS CFX to observe the changes in flow behavior at various sections of the model. The computed results agree well with clinical observations.

Original languageEnglish
Title of host publication2011 IEEE 3rd International Conference on Communication Software and Networks, ICCSN 2011
Pages245-248
Number of pages4
DOIs
Publication statusPublished - 29-09-2011
Event2011 IEEE 3rd International Conference on Communication Software and Networks, ICCSN 2011 - Xi'an, China
Duration: 27-05-201129-05-2011

Conference

Conference2011 IEEE 3rd International Conference on Communication Software and Networks, ICCSN 2011
CountryChina
CityXi'an
Period27-05-1129-05-11

Fingerprint

Computational fluid dynamics
Natural sciences computing
Dynamic analysis
Blood
Ultrasonics
Fluids

All Science Journal Classification (ASJC) codes

  • Computer Networks and Communications
  • Software

Cite this

Khader, S. M. A., Pai, B. R., Ayachit, A., Rao, V. R. K., & Kamath, S. G. (2011). Comparison of flow in normal and stenosed carotid bulb. In 2011 IEEE 3rd International Conference on Communication Software and Networks, ICCSN 2011 (pp. 245-248). [6014889] https://doi.org/10.1109/ICCSN.2011.6014889
Khader, S. M Abdul ; Pai, B. Raghuvir ; Ayachit, Anurag ; Rao, V. R K ; Kamath, S. Ganesh. / Comparison of flow in normal and stenosed carotid bulb. 2011 IEEE 3rd International Conference on Communication Software and Networks, ICCSN 2011. 2011. pp. 245-248
@inproceedings{6d4d9911b0a04293ba04bd3317bf41ff,
title = "Comparison of flow in normal and stenosed carotid bulb",
abstract = "Computational Fluid Dynamics (CFD) is one of the growing challenges in scientific computing wherein the complex fluid domains are analyzed. One such domain is blood flow analysis through elastic arteries. Such an analysis can be a promising future for the medical field where realistic physiological conditions can be simulated to observe the flow behavior. In the present study, a case study of normal and stenosed carotid bifurcation is simulated for a Newtonian case. The models are generated in CATIA based on the clinical data obtained from Ultrasound Doppler from a patient. A transient CFD analysis is performed for several pulse cycles for normal and stenosed models using ANSYS CFX to observe the changes in flow behavior at various sections of the model. The computed results agree well with clinical observations.",
author = "Khader, {S. M Abdul} and Pai, {B. Raghuvir} and Anurag Ayachit and Rao, {V. R K} and Kamath, {S. Ganesh}",
year = "2011",
month = "9",
day = "29",
doi = "10.1109/ICCSN.2011.6014889",
language = "English",
isbn = "9781612844855",
pages = "245--248",
booktitle = "2011 IEEE 3rd International Conference on Communication Software and Networks, ICCSN 2011",

}

Khader, SMA, Pai, BR, Ayachit, A, Rao, VRK & Kamath, SG 2011, Comparison of flow in normal and stenosed carotid bulb. in 2011 IEEE 3rd International Conference on Communication Software and Networks, ICCSN 2011., 6014889, pp. 245-248, 2011 IEEE 3rd International Conference on Communication Software and Networks, ICCSN 2011, Xi'an, China, 27-05-11. https://doi.org/10.1109/ICCSN.2011.6014889

Comparison of flow in normal and stenosed carotid bulb. / Khader, S. M Abdul; Pai, B. Raghuvir; Ayachit, Anurag; Rao, V. R K; Kamath, S. Ganesh.

2011 IEEE 3rd International Conference on Communication Software and Networks, ICCSN 2011. 2011. p. 245-248 6014889.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

TY - GEN

T1 - Comparison of flow in normal and stenosed carotid bulb

AU - Khader, S. M Abdul

AU - Pai, B. Raghuvir

AU - Ayachit, Anurag

AU - Rao, V. R K

AU - Kamath, S. Ganesh

PY - 2011/9/29

Y1 - 2011/9/29

N2 - Computational Fluid Dynamics (CFD) is one of the growing challenges in scientific computing wherein the complex fluid domains are analyzed. One such domain is blood flow analysis through elastic arteries. Such an analysis can be a promising future for the medical field where realistic physiological conditions can be simulated to observe the flow behavior. In the present study, a case study of normal and stenosed carotid bifurcation is simulated for a Newtonian case. The models are generated in CATIA based on the clinical data obtained from Ultrasound Doppler from a patient. A transient CFD analysis is performed for several pulse cycles for normal and stenosed models using ANSYS CFX to observe the changes in flow behavior at various sections of the model. The computed results agree well with clinical observations.

AB - Computational Fluid Dynamics (CFD) is one of the growing challenges in scientific computing wherein the complex fluid domains are analyzed. One such domain is blood flow analysis through elastic arteries. Such an analysis can be a promising future for the medical field where realistic physiological conditions can be simulated to observe the flow behavior. In the present study, a case study of normal and stenosed carotid bifurcation is simulated for a Newtonian case. The models are generated in CATIA based on the clinical data obtained from Ultrasound Doppler from a patient. A transient CFD analysis is performed for several pulse cycles for normal and stenosed models using ANSYS CFX to observe the changes in flow behavior at various sections of the model. The computed results agree well with clinical observations.

UR - http://www.scopus.com/inward/record.url?scp=80053164685&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=80053164685&partnerID=8YFLogxK

U2 - 10.1109/ICCSN.2011.6014889

DO - 10.1109/ICCSN.2011.6014889

M3 - Conference contribution

SN - 9781612844855

SP - 245

EP - 248

BT - 2011 IEEE 3rd International Conference on Communication Software and Networks, ICCSN 2011

ER -

Khader SMA, Pai BR, Ayachit A, Rao VRK, Kamath SG. Comparison of flow in normal and stenosed carotid bulb. In 2011 IEEE 3rd International Conference on Communication Software and Networks, ICCSN 2011. 2011. p. 245-248. 6014889 https://doi.org/10.1109/ICCSN.2011.6014889