Comparison of impact strength of acrylic resin reinforced with kevlar and polyethylene fibres.

G. Kamath, K. Bhargava

Research output: Contribution to journalArticle

Abstract

The present study was done to evaluate the impact strengths of heat-activated acrylic resins reinforced with Kevlar fibres, polyethylene fibres and unreinforced heat activated acrylic resin. Each of three groups had 25 specimens. Brass rods of uniform length of 40 mm and diameter of 8 mm were used to prepare the moulds. A combination of long fibres (40 mm length) and short fibres (6 mm length) were used. The total amount of fibres incorporated was limited to 2% by weight of the resin matrix. Short and long fibres of equal weight were incorporated. The short fibres were mixed with polymer and monomer and packed into the mould, while, the long axis of the specimen, perpendicular to the applied force. The specimens were then processed. Impact strength testing was done on Hounsfield's impact testing machine. Kevlar fibre reinforced heat activated acrylic resin specimens recorded higher mean impact strength of 0.8464 Joules, while polyethylene fibres reinforced heat activated acrylic resin recorded mean impact strength of 0.7596 joules. The unreinforced heat activated acrylic resin recorded mean impact strength of 0.3440 Joules.

Original languageEnglish
Pages (from-to)108-111
Number of pages4
JournalIndian journal of dental research : official publication of Indian Society for Dental Research
Volume13
Issue number2
Publication statusPublished - 01-04-2002

Fingerprint

Acrylic Resins
Polyethylene
Hot Temperature
Fungi
Weights and Measures
Polymers

All Science Journal Classification (ASJC) codes

  • Dentistry(all)

Cite this

@article{3071fce1fe60411c9663ec1ee0996c8d,
title = "Comparison of impact strength of acrylic resin reinforced with kevlar and polyethylene fibres.",
abstract = "The present study was done to evaluate the impact strengths of heat-activated acrylic resins reinforced with Kevlar fibres, polyethylene fibres and unreinforced heat activated acrylic resin. Each of three groups had 25 specimens. Brass rods of uniform length of 40 mm and diameter of 8 mm were used to prepare the moulds. A combination of long fibres (40 mm length) and short fibres (6 mm length) were used. The total amount of fibres incorporated was limited to 2{\%} by weight of the resin matrix. Short and long fibres of equal weight were incorporated. The short fibres were mixed with polymer and monomer and packed into the mould, while, the long axis of the specimen, perpendicular to the applied force. The specimens were then processed. Impact strength testing was done on Hounsfield's impact testing machine. Kevlar fibre reinforced heat activated acrylic resin specimens recorded higher mean impact strength of 0.8464 Joules, while polyethylene fibres reinforced heat activated acrylic resin recorded mean impact strength of 0.7596 joules. The unreinforced heat activated acrylic resin recorded mean impact strength of 0.3440 Joules.",
author = "G. Kamath and K. Bhargava",
year = "2002",
month = "4",
day = "1",
language = "English",
volume = "13",
pages = "108--111",
journal = "Indian Journal of Dental Research",
issn = "0970-9290",
publisher = "Medknow Publications and Media Pvt. Ltd",
number = "2",

}

TY - JOUR

T1 - Comparison of impact strength of acrylic resin reinforced with kevlar and polyethylene fibres.

AU - Kamath, G.

AU - Bhargava, K.

PY - 2002/4/1

Y1 - 2002/4/1

N2 - The present study was done to evaluate the impact strengths of heat-activated acrylic resins reinforced with Kevlar fibres, polyethylene fibres and unreinforced heat activated acrylic resin. Each of three groups had 25 specimens. Brass rods of uniform length of 40 mm and diameter of 8 mm were used to prepare the moulds. A combination of long fibres (40 mm length) and short fibres (6 mm length) were used. The total amount of fibres incorporated was limited to 2% by weight of the resin matrix. Short and long fibres of equal weight were incorporated. The short fibres were mixed with polymer and monomer and packed into the mould, while, the long axis of the specimen, perpendicular to the applied force. The specimens were then processed. Impact strength testing was done on Hounsfield's impact testing machine. Kevlar fibre reinforced heat activated acrylic resin specimens recorded higher mean impact strength of 0.8464 Joules, while polyethylene fibres reinforced heat activated acrylic resin recorded mean impact strength of 0.7596 joules. The unreinforced heat activated acrylic resin recorded mean impact strength of 0.3440 Joules.

AB - The present study was done to evaluate the impact strengths of heat-activated acrylic resins reinforced with Kevlar fibres, polyethylene fibres and unreinforced heat activated acrylic resin. Each of three groups had 25 specimens. Brass rods of uniform length of 40 mm and diameter of 8 mm were used to prepare the moulds. A combination of long fibres (40 mm length) and short fibres (6 mm length) were used. The total amount of fibres incorporated was limited to 2% by weight of the resin matrix. Short and long fibres of equal weight were incorporated. The short fibres were mixed with polymer and monomer and packed into the mould, while, the long axis of the specimen, perpendicular to the applied force. The specimens were then processed. Impact strength testing was done on Hounsfield's impact testing machine. Kevlar fibre reinforced heat activated acrylic resin specimens recorded higher mean impact strength of 0.8464 Joules, while polyethylene fibres reinforced heat activated acrylic resin recorded mean impact strength of 0.7596 joules. The unreinforced heat activated acrylic resin recorded mean impact strength of 0.3440 Joules.

UR - http://www.scopus.com/inward/record.url?scp=0036545776&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0036545776&partnerID=8YFLogxK

M3 - Article

C2 - 12420577

AN - SCOPUS:0036545776

VL - 13

SP - 108

EP - 111

JO - Indian Journal of Dental Research

JF - Indian Journal of Dental Research

SN - 0970-9290

IS - 2

ER -