Comparison of the different controlling techniques for buck converter in LED application

Research output: Contribution to journalArticle

Abstract

This paper recounts the design and construction of various controlling techniques for buck converter. If the designed controller for any converter is not proper which leads to high overshoot and steady state error, and its dynamic response varies with changes in load, especially at high load current conditions. The lead-lag controller for the converter is desgined using classical control theory,Bode Plot technique is used to examine the stability of the system.By using deravetive part of the PID controller on output signal instead of voltage error signal,this combination of control technique reduces the overshoot and settling time,and how the transient response will be affected if deravetive controller is in the forward path.

Original languageEnglish
Pages (from-to)256-264
Number of pages9
JournalInternational Journal of Power Electronics and Drive Systems
Volume10
Issue number1
DOIs
Publication statusPublished - 01-03-2019

Fingerprint

Light emitting diodes
Controllers
Control theory
Transient analysis
Dynamic response
Lead
Electric potential

All Science Journal Classification (ASJC) codes

  • Energy Engineering and Power Technology
  • Electrical and Electronic Engineering

Cite this

@article{9961c1dd899443deb8365c47b9d2dee8,
title = "Comparison of the different controlling techniques for buck converter in LED application",
abstract = "This paper recounts the design and construction of various controlling techniques for buck converter. If the designed controller for any converter is not proper which leads to high overshoot and steady state error, and its dynamic response varies with changes in load, especially at high load current conditions. The lead-lag controller for the converter is desgined using classical control theory,Bode Plot technique is used to examine the stability of the system.By using deravetive part of the PID controller on output signal instead of voltage error signal,this combination of control technique reduces the overshoot and settling time,and how the transient response will be affected if deravetive controller is in the forward path.",
author = "Shwetha, {D. V.} and Paragond, {Lakshman Rao S.}",
year = "2019",
month = "3",
day = "1",
doi = "10.11591/ijpeds.v10n1.pp256-264",
language = "English",
volume = "10",
pages = "256--264",
journal = "International Journal of Power Electronics and Drive Systems",
issn = "2088-8694",
publisher = "Institute of Advanced Engineering and Science (IAES)",
number = "1",

}

TY - JOUR

T1 - Comparison of the different controlling techniques for buck converter in LED application

AU - Shwetha, D. V.

AU - Paragond, Lakshman Rao S.

PY - 2019/3/1

Y1 - 2019/3/1

N2 - This paper recounts the design and construction of various controlling techniques for buck converter. If the designed controller for any converter is not proper which leads to high overshoot and steady state error, and its dynamic response varies with changes in load, especially at high load current conditions. The lead-lag controller for the converter is desgined using classical control theory,Bode Plot technique is used to examine the stability of the system.By using deravetive part of the PID controller on output signal instead of voltage error signal,this combination of control technique reduces the overshoot and settling time,and how the transient response will be affected if deravetive controller is in the forward path.

AB - This paper recounts the design and construction of various controlling techniques for buck converter. If the designed controller for any converter is not proper which leads to high overshoot and steady state error, and its dynamic response varies with changes in load, especially at high load current conditions. The lead-lag controller for the converter is desgined using classical control theory,Bode Plot technique is used to examine the stability of the system.By using deravetive part of the PID controller on output signal instead of voltage error signal,this combination of control technique reduces the overshoot and settling time,and how the transient response will be affected if deravetive controller is in the forward path.

UR - http://www.scopus.com/inward/record.url?scp=85059619555&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85059619555&partnerID=8YFLogxK

U2 - 10.11591/ijpeds.v10n1.pp256-264

DO - 10.11591/ijpeds.v10n1.pp256-264

M3 - Article

VL - 10

SP - 256

EP - 264

JO - International Journal of Power Electronics and Drive Systems

JF - International Journal of Power Electronics and Drive Systems

SN - 2088-8694

IS - 1

ER -