Abstract
This paper reports the results of measurements performed in a test room to test how digital camera can be used as luminance meter and thus to investigate the lighting control scheme based on the inputs coming from camera. An indoor lighting control scheme which adapts according to the daylight availability is presented in this work. The camera calibration procedure based on High Dynamic Range Imaging technique is used to obtain the camera response function which allows to relate pixel values obtained from the image and the photopic luminance values. Luminance gradient evaluation for the uniformity analysis is discussed for the test room.
Original language | English |
---|---|
Pages (from-to) | 99-105 |
Number of pages | 7 |
Journal | International Journal of Engineering and Technology(UAE) |
Volume | 7 |
Issue number | 2 |
DOIs | |
Publication status | Published - 01-01-2018 |
Fingerprint
All Science Journal Classification (ASJC) codes
- Biotechnology
- Computer Science (miscellaneous)
- Environmental Engineering
- Chemical Engineering(all)
- Engineering(all)
- Hardware and Architecture
Cite this
}
Control and evaluation of room interior lighting using digital camera as the sensor. / Varghese, Susan G.; Kurian, Ciji Pearl; George, V. I.; Sudheer Kumar, T. S.
In: International Journal of Engineering and Technology(UAE), Vol. 7, No. 2, 01.01.2018, p. 99-105.Research output: Contribution to journal › Article
TY - JOUR
T1 - Control and evaluation of room interior lighting using digital camera as the sensor
AU - Varghese, Susan G.
AU - Kurian, Ciji Pearl
AU - George, V. I.
AU - Sudheer Kumar, T. S.
PY - 2018/1/1
Y1 - 2018/1/1
N2 - This paper reports the results of measurements performed in a test room to test how digital camera can be used as luminance meter and thus to investigate the lighting control scheme based on the inputs coming from camera. An indoor lighting control scheme which adapts according to the daylight availability is presented in this work. The camera calibration procedure based on High Dynamic Range Imaging technique is used to obtain the camera response function which allows to relate pixel values obtained from the image and the photopic luminance values. Luminance gradient evaluation for the uniformity analysis is discussed for the test room.
AB - This paper reports the results of measurements performed in a test room to test how digital camera can be used as luminance meter and thus to investigate the lighting control scheme based on the inputs coming from camera. An indoor lighting control scheme which adapts according to the daylight availability is presented in this work. The camera calibration procedure based on High Dynamic Range Imaging technique is used to obtain the camera response function which allows to relate pixel values obtained from the image and the photopic luminance values. Luminance gradient evaluation for the uniformity analysis is discussed for the test room.
UR - http://www.scopus.com/inward/record.url?scp=85046084522&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85046084522&partnerID=8YFLogxK
U2 - 10.14419/ijet.v7i2.21.11844
DO - 10.14419/ijet.v7i2.21.11844
M3 - Article
AN - SCOPUS:85046084522
VL - 7
SP - 99
EP - 105
JO - International Journal of Engineering and Technology(UAE)
JF - International Journal of Engineering and Technology(UAE)
SN - 2227-524X
IS - 2
ER -