Design of fuzzy-PID controller for first order non-linear liquid level system

V. Sravani, Sumit Shinde

Research output: Contribution to journalArticle

Abstract

This paper deals with a controlling of first order non-linear liquid system to desired level. Mathematical model[1] of non- linear liquid level system is derived using basic principles of science. Different control strategies are applied on level system like conventional Proportional -Integral-derivative (PID) controller which gave unsatisfactory response when used alone. Fuzzy controller[2] was used, which is based on set of empirical rules to meet the desired set-point .Fuzzy control worked better than PID control but there were several drawbacks of fuzzy controller which were addressed by combining the both the controllers and introducing that in level control loop. This paper compares the response of all three controllers-PID, Fuzzy and Fuzzy-PID[4] after simulation in LabVIEW[3]. Integral of Time-Weighted Absolute value of Error (ITAE) was calculated and it was found that for fuzzy-PID, value of ITAE was best. Fuzzy-PID control was best suited for non-linear liquid level system with water as the process liquid, as it had the best set point tracking, least oscillations and the value of ITAE was the least.

Original languageEnglish
Pages (from-to)151-157
Number of pages7
JournalInternational Journal of Control Theory and Applications
Volume9
Issue number39
Publication statusPublished - 01-01-2016
Externally publishedYes

Fingerprint

Derivatives
Controllers
Liquids
Level control
Fuzzy control
Mathematical models
Water

All Science Journal Classification (ASJC) codes

  • Computer Science(all)

Cite this

@article{f5524da041044fe3b1ffe890faf7c2ef,
title = "Design of fuzzy-PID controller for first order non-linear liquid level system",
abstract = "This paper deals with a controlling of first order non-linear liquid system to desired level. Mathematical model[1] of non- linear liquid level system is derived using basic principles of science. Different control strategies are applied on level system like conventional Proportional -Integral-derivative (PID) controller which gave unsatisfactory response when used alone. Fuzzy controller[2] was used, which is based on set of empirical rules to meet the desired set-point .Fuzzy control worked better than PID control but there were several drawbacks of fuzzy controller which were addressed by combining the both the controllers and introducing that in level control loop. This paper compares the response of all three controllers-PID, Fuzzy and Fuzzy-PID[4] after simulation in LabVIEW[3]. Integral of Time-Weighted Absolute value of Error (ITAE) was calculated and it was found that for fuzzy-PID, value of ITAE was best. Fuzzy-PID control was best suited for non-linear liquid level system with water as the process liquid, as it had the best set point tracking, least oscillations and the value of ITAE was the least.",
author = "V. Sravani and Sumit Shinde",
year = "2016",
month = "1",
day = "1",
language = "English",
volume = "9",
pages = "151--157",
journal = "International Journal of Control Theory and Applications",
issn = "0974-5572",
publisher = "Serials Publications",
number = "39",

}

Design of fuzzy-PID controller for first order non-linear liquid level system. / Sravani, V.; Shinde, Sumit.

In: International Journal of Control Theory and Applications, Vol. 9, No. 39, 01.01.2016, p. 151-157.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Design of fuzzy-PID controller for first order non-linear liquid level system

AU - Sravani, V.

AU - Shinde, Sumit

PY - 2016/1/1

Y1 - 2016/1/1

N2 - This paper deals with a controlling of first order non-linear liquid system to desired level. Mathematical model[1] of non- linear liquid level system is derived using basic principles of science. Different control strategies are applied on level system like conventional Proportional -Integral-derivative (PID) controller which gave unsatisfactory response when used alone. Fuzzy controller[2] was used, which is based on set of empirical rules to meet the desired set-point .Fuzzy control worked better than PID control but there were several drawbacks of fuzzy controller which were addressed by combining the both the controllers and introducing that in level control loop. This paper compares the response of all three controllers-PID, Fuzzy and Fuzzy-PID[4] after simulation in LabVIEW[3]. Integral of Time-Weighted Absolute value of Error (ITAE) was calculated and it was found that for fuzzy-PID, value of ITAE was best. Fuzzy-PID control was best suited for non-linear liquid level system with water as the process liquid, as it had the best set point tracking, least oscillations and the value of ITAE was the least.

AB - This paper deals with a controlling of first order non-linear liquid system to desired level. Mathematical model[1] of non- linear liquid level system is derived using basic principles of science. Different control strategies are applied on level system like conventional Proportional -Integral-derivative (PID) controller which gave unsatisfactory response when used alone. Fuzzy controller[2] was used, which is based on set of empirical rules to meet the desired set-point .Fuzzy control worked better than PID control but there were several drawbacks of fuzzy controller which were addressed by combining the both the controllers and introducing that in level control loop. This paper compares the response of all three controllers-PID, Fuzzy and Fuzzy-PID[4] after simulation in LabVIEW[3]. Integral of Time-Weighted Absolute value of Error (ITAE) was calculated and it was found that for fuzzy-PID, value of ITAE was best. Fuzzy-PID control was best suited for non-linear liquid level system with water as the process liquid, as it had the best set point tracking, least oscillations and the value of ITAE was the least.

UR - http://www.scopus.com/inward/record.url?scp=85010654082&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85010654082&partnerID=8YFLogxK

M3 - Article

VL - 9

SP - 151

EP - 157

JO - International Journal of Control Theory and Applications

JF - International Journal of Control Theory and Applications

SN - 0974-5572

IS - 39

ER -