Autofluorescence spectroscopy offer noninvasive and promising tools for the detection of alternations biochemical compositions of tissues and cells, in presence of disease. They have the added advantage of being highly objective due to the fact that diagnostic evaluation is by statistical methods, eliminating errors from lack of experience, fatigue factor, and subjectivity of visual perceptions. The present research work involves in designing and assembling of a low cost, miniature oral cancer screening device with for routine clinical applications. A miniature system was designed and assembled with much smaller and cost-effective components like compact light source and miniature spectrometer, in a hand-held unit configuration. The performance of the system was evaluated using animal -mouse- SCC model. The current system can be used in handheld operation, which makes it very useful for many applications like, screening of squamous cell carcinoma susceptible population.

Original languageEnglish
Title of host publicationClinical and Preclinical Optical Diagnostics
PublisherSPIE
Volume10411
ISBN (Electronic)9781510612808
DOIs
Publication statusPublished - 01-01-2017
EventClinical and Preclinical Optical Diagnostics 2017 - Munich, Germany
Duration: 25-06-201727-06-2017

Conference

ConferenceClinical and Preclinical Optical Diagnostics 2017
CountryGermany
CityMunich
Period25-06-1727-06-17

Fingerprint

Early Diagnosis
Squamous Cell Carcinoma
Screening
screening
cancer
Costs and Cost Analysis
Equipment and Supplies
Visual Perception
Mouth Neoplasms
visual perception
alternations
assembling
Early Detection of Cancer
Fatigue
mice
Light sources
animals
Spectrometers
Costs
Spectrum Analysis

All Science Journal Classification (ASJC) codes

  • Electronic, Optical and Magnetic Materials
  • Atomic and Molecular Physics, and Optics
  • Biomaterials
  • Radiology Nuclear Medicine and imaging

Cite this

@inproceedings{db9087e4bf35493e9d80d71bc291ec15,
title = "Development of a miniature autofluorescence device for the early diagnosis of squamous cell carcinoma",
abstract = "Autofluorescence spectroscopy offer noninvasive and promising tools for the detection of alternations biochemical compositions of tissues and cells, in presence of disease. They have the added advantage of being highly objective due to the fact that diagnostic evaluation is by statistical methods, eliminating errors from lack of experience, fatigue factor, and subjectivity of visual perceptions. The present research work involves in designing and assembling of a low cost, miniature oral cancer screening device with for routine clinical applications. A miniature system was designed and assembled with much smaller and cost-effective components like compact light source and miniature spectrometer, in a hand-held unit configuration. The performance of the system was evaluated using animal -mouse- SCC model. The current system can be used in handheld operation, which makes it very useful for many applications like, screening of squamous cell carcinoma susceptible population.",
author = "Ajeetkumar Patil and Swati, {Rao K.} and Unnikrishnan, {V. K.} and Pai, {Keerthilatha M.} and Kartha, {V. B.} and Santhosh Chidangil",
year = "2017",
month = "1",
day = "1",
doi = "10.1117/12.2282888",
language = "English",
volume = "10411",
booktitle = "Clinical and Preclinical Optical Diagnostics",
publisher = "SPIE",
address = "United States",

}

Patil, A, Swati, RK, Unnikrishnan, VK, Pai, KM, Kartha, VB & Chidangil, S 2017, Development of a miniature autofluorescence device for the early diagnosis of squamous cell carcinoma. in Clinical and Preclinical Optical Diagnostics. vol. 10411, 104110V, SPIE, Clinical and Preclinical Optical Diagnostics 2017, Munich, Germany, 25-06-17. https://doi.org/10.1117/12.2282888

Development of a miniature autofluorescence device for the early diagnosis of squamous cell carcinoma. / Patil, Ajeetkumar; Swati, Rao K.; Unnikrishnan, V. K.; Pai, Keerthilatha M.; Kartha, V. B.; Chidangil, Santhosh.

Clinical and Preclinical Optical Diagnostics. Vol. 10411 SPIE, 2017. 104110V.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

TY - GEN

T1 - Development of a miniature autofluorescence device for the early diagnosis of squamous cell carcinoma

AU - Patil, Ajeetkumar

AU - Swati, Rao K.

AU - Unnikrishnan, V. K.

AU - Pai, Keerthilatha M.

AU - Kartha, V. B.

AU - Chidangil, Santhosh

PY - 2017/1/1

Y1 - 2017/1/1

N2 - Autofluorescence spectroscopy offer noninvasive and promising tools for the detection of alternations biochemical compositions of tissues and cells, in presence of disease. They have the added advantage of being highly objective due to the fact that diagnostic evaluation is by statistical methods, eliminating errors from lack of experience, fatigue factor, and subjectivity of visual perceptions. The present research work involves in designing and assembling of a low cost, miniature oral cancer screening device with for routine clinical applications. A miniature system was designed and assembled with much smaller and cost-effective components like compact light source and miniature spectrometer, in a hand-held unit configuration. The performance of the system was evaluated using animal -mouse- SCC model. The current system can be used in handheld operation, which makes it very useful for many applications like, screening of squamous cell carcinoma susceptible population.

AB - Autofluorescence spectroscopy offer noninvasive and promising tools for the detection of alternations biochemical compositions of tissues and cells, in presence of disease. They have the added advantage of being highly objective due to the fact that diagnostic evaluation is by statistical methods, eliminating errors from lack of experience, fatigue factor, and subjectivity of visual perceptions. The present research work involves in designing and assembling of a low cost, miniature oral cancer screening device with for routine clinical applications. A miniature system was designed and assembled with much smaller and cost-effective components like compact light source and miniature spectrometer, in a hand-held unit configuration. The performance of the system was evaluated using animal -mouse- SCC model. The current system can be used in handheld operation, which makes it very useful for many applications like, screening of squamous cell carcinoma susceptible population.

UR - http://www.scopus.com/inward/record.url?scp=85033556068&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85033556068&partnerID=8YFLogxK

U2 - 10.1117/12.2282888

DO - 10.1117/12.2282888

M3 - Conference contribution

AN - SCOPUS:85033556068

VL - 10411

BT - Clinical and Preclinical Optical Diagnostics

PB - SPIE

ER -