Discrepancy in Optical & Mechanical Method in Coagulation Tests in a Turbid Sample

Swati Aggarwal, Deepak M. Nayak, Chethan Manohar

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

Automated coagulation analyzers have replaced manual methods to meet the ever-increasing test load in many laboratories. Of the different methods, two distinct methods exist based on optical and mechanical clot detection (magnetic steel ball method). In optical method the detection of clot formation is measured by a change in optical density (OD) of a test sample. Mechanical clot detection technology, involves monitoring the movement of a steel ball within the test solution using a magnetic sensor. There are limited studies comparing both these methods and they have conflicting results regarding the effect of plasma turbidity on the final result. We report a case where a plasma factor (lipemia) caused prolongation of both PT and APTT, as measured by the photo optical method.

Original languageEnglish
Pages (from-to)402-404
Number of pages3
JournalIndian Journal of Hematology and Blood Transfusion
Volume30
DOIs
Publication statusPublished - 01-01-2014

Fingerprint

Steel
Hyperlipidemias
Technology

All Science Journal Classification (ASJC) codes

  • Hematology

Cite this

Aggarwal, Swati ; Nayak, Deepak M. ; Manohar, Chethan. / Discrepancy in Optical & Mechanical Method in Coagulation Tests in a Turbid Sample. In: Indian Journal of Hematology and Blood Transfusion. 2014 ; Vol. 30. pp. 402-404.
@article{c732d50d0af54474be78de42d69094b4,
title = "Discrepancy in Optical & Mechanical Method in Coagulation Tests in a Turbid Sample",
abstract = "Automated coagulation analyzers have replaced manual methods to meet the ever-increasing test load in many laboratories. Of the different methods, two distinct methods exist based on optical and mechanical clot detection (magnetic steel ball method). In optical method the detection of clot formation is measured by a change in optical density (OD) of a test sample. Mechanical clot detection technology, involves monitoring the movement of a steel ball within the test solution using a magnetic sensor. There are limited studies comparing both these methods and they have conflicting results regarding the effect of plasma turbidity on the final result. We report a case where a plasma factor (lipemia) caused prolongation of both PT and APTT, as measured by the photo optical method.",
author = "Swati Aggarwal and Nayak, {Deepak M.} and Chethan Manohar",
year = "2014",
month = "1",
day = "1",
doi = "10.1007/s12288-014-0438-5",
language = "English",
volume = "30",
pages = "402--404",
journal = "Indian Journal of Hematology and Blood Transfusion",
issn = "0971-4502",
publisher = "Springer India",

}

Discrepancy in Optical & Mechanical Method in Coagulation Tests in a Turbid Sample. / Aggarwal, Swati; Nayak, Deepak M.; Manohar, Chethan.

In: Indian Journal of Hematology and Blood Transfusion, Vol. 30, 01.01.2014, p. 402-404.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Discrepancy in Optical & Mechanical Method in Coagulation Tests in a Turbid Sample

AU - Aggarwal, Swati

AU - Nayak, Deepak M.

AU - Manohar, Chethan

PY - 2014/1/1

Y1 - 2014/1/1

N2 - Automated coagulation analyzers have replaced manual methods to meet the ever-increasing test load in many laboratories. Of the different methods, two distinct methods exist based on optical and mechanical clot detection (magnetic steel ball method). In optical method the detection of clot formation is measured by a change in optical density (OD) of a test sample. Mechanical clot detection technology, involves monitoring the movement of a steel ball within the test solution using a magnetic sensor. There are limited studies comparing both these methods and they have conflicting results regarding the effect of plasma turbidity on the final result. We report a case where a plasma factor (lipemia) caused prolongation of both PT and APTT, as measured by the photo optical method.

AB - Automated coagulation analyzers have replaced manual methods to meet the ever-increasing test load in many laboratories. Of the different methods, two distinct methods exist based on optical and mechanical clot detection (magnetic steel ball method). In optical method the detection of clot formation is measured by a change in optical density (OD) of a test sample. Mechanical clot detection technology, involves monitoring the movement of a steel ball within the test solution using a magnetic sensor. There are limited studies comparing both these methods and they have conflicting results regarding the effect of plasma turbidity on the final result. We report a case where a plasma factor (lipemia) caused prolongation of both PT and APTT, as measured by the photo optical method.

UR - http://www.scopus.com/inward/record.url?scp=84924764838&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84924764838&partnerID=8YFLogxK

U2 - 10.1007/s12288-014-0438-5

DO - 10.1007/s12288-014-0438-5

M3 - Article

VL - 30

SP - 402

EP - 404

JO - Indian Journal of Hematology and Blood Transfusion

JF - Indian Journal of Hematology and Blood Transfusion

SN - 0971-4502

ER -