TY - JOUR
T1 - Effect of different herbal tea preparations on the color stability of glass ionomer cements
AU - Haque, Shehla Wasim
AU - Muliya, Vidya Saraswathi
AU - Somayaji, Krishnaraj
AU - Pentapati, Kalyana Chakravarthy
N1 - Publisher Copyright:
© 2021 Haque et al.
PY - 2021
Y1 - 2021
N2 - Objective: To compare the color stability of the newer glass ionomer cements (GIC) when exposed to “Green tea” (GT), “Tulsi tea” (TT), and “Areca tea” (AT) using spectrophotometric analysis. Materials and Methods: We selected commercially available GC Fuji IX GP EXTRA and Ketac Universal for this study. Eighty disc-shaped samples were made using a mold, which were immersed in the freshly prepared test solutions (distilled water, GT, TT, and AT) for 15 minutes per day for 60 days. The color estimation was done using a spectrophotometer. Results: GC Fuji IX samples had a significantly higher mean difference in ΔE value than Ketac Universal when immersed in GT, AT, and control (P<0.001, 0.018, and <0.001), respectively. With GC Fuji IX, GT and AT stained more than TT and control solutions. Samples of Ketac Universal showed a significantly higher mean difference in ΔE values when immersed in AT, followed by GT, TT, and control. Conclusion: Within the study’s limitations, we conclude that both the GICs exhibited staining over time on exposure to all the test solutions. Ketac Universal demonstrated lower staining potential than GIC Fuji IX GP Extra for GT and AT.
AB - Objective: To compare the color stability of the newer glass ionomer cements (GIC) when exposed to “Green tea” (GT), “Tulsi tea” (TT), and “Areca tea” (AT) using spectrophotometric analysis. Materials and Methods: We selected commercially available GC Fuji IX GP EXTRA and Ketac Universal for this study. Eighty disc-shaped samples were made using a mold, which were immersed in the freshly prepared test solutions (distilled water, GT, TT, and AT) for 15 minutes per day for 60 days. The color estimation was done using a spectrophotometer. Results: GC Fuji IX samples had a significantly higher mean difference in ΔE value than Ketac Universal when immersed in GT, AT, and control (P<0.001, 0.018, and <0.001), respectively. With GC Fuji IX, GT and AT stained more than TT and control solutions. Samples of Ketac Universal showed a significantly higher mean difference in ΔE values when immersed in AT, followed by GT, TT, and control. Conclusion: Within the study’s limitations, we conclude that both the GICs exhibited staining over time on exposure to all the test solutions. Ketac Universal demonstrated lower staining potential than GIC Fuji IX GP Extra for GT and AT.
UR - http://www.scopus.com/inward/record.url?scp=85104765033&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85104765033&partnerID=8YFLogxK
U2 - 10.2147/CCIDE.S306919
DO - 10.2147/CCIDE.S306919
M3 - Article
AN - SCOPUS:85104765033
SN - 1179-1357
VL - 13
SP - 121
EP - 125
JO - Clinical, Cosmetic and Investigational Dentistry
JF - Clinical, Cosmetic and Investigational Dentistry
ER -