Effect of positive airway pressure during pre-oxygenation and induction of anaesthesia upon safe duration of apnoea

Melveetil S. Sreejit, Venkateswaran Ramkumar

Research output: Contribution to journalArticle

7 Citations (Scopus)

Abstract

Background and Aims: Induction of general anaesthesia per se as also the use of 100% oxygen during induction of anaesthesia, results in the development of atelectasis in dependent lung regions within minutes of anaesthetic induction. We aimed to assess the effect of application of a continuous positive airway pressure (CPAP) of 5 cm H 2 O during pre-oxygenation and induction of anaesthesia on the period of apnoea before the occurrence of clinically significant desaturation. Methods: In this prospective, randomised, and double-blind study, 40 patients posted for elective surgery were enrolled. Duration of apnoea was measured as the time from the administration of succinylcholine hydrochloride to the time when oxygen saturation fell to 93%. Student’s t-test was used for comparing the duration of apnoea. Results: The safe duration of apnoea was found to be significantly longer in patients receiving CPAP of 5 cm H2 O (Group P; n = 16) compared to the group receiving no CPAP (Group Z; n = 20), that is, 496.56 ± 71.68 s versus 273.00 ± 69.31 s (P < 0.001). Conclusion: The application of CPAP of 5 cm H 2 O using a Mapleson “A” circuit with a fixed positive end-expiratory pressure device during 5 min of pre-oxygenation with 100% oxygen prior to the induction of anaesthesia provides a clearly longer duration of apnoea before clinically significant arterial desaturation occurs.

Original languageEnglish
Pages (from-to)216-221
Number of pages6
JournalIndian Journal of Anaesthesia
Volume59
Issue number4
DOIs
Publication statusPublished - 01-01-2015
Externally publishedYes

Fingerprint

Apnea
Continuous Positive Airway Pressure
Anesthesia
Pressure
Oxygen
Succinylcholine
Pulmonary Atelectasis
Positive-Pressure Respiration
Double-Blind Method
General Anesthesia
Anesthetics
Students
Equipment and Supplies
Lung

All Science Journal Classification (ASJC) codes

  • Anesthesiology and Pain Medicine

Cite this

@article{263cc3b506a943b99a8babcd6f8f6127,
title = "Effect of positive airway pressure during pre-oxygenation and induction of anaesthesia upon safe duration of apnoea",
abstract = "Background and Aims: Induction of general anaesthesia per se as also the use of 100{\%} oxygen during induction of anaesthesia, results in the development of atelectasis in dependent lung regions within minutes of anaesthetic induction. We aimed to assess the effect of application of a continuous positive airway pressure (CPAP) of 5 cm H 2 O during pre-oxygenation and induction of anaesthesia on the period of apnoea before the occurrence of clinically significant desaturation. Methods: In this prospective, randomised, and double-blind study, 40 patients posted for elective surgery were enrolled. Duration of apnoea was measured as the time from the administration of succinylcholine hydrochloride to the time when oxygen saturation fell to 93{\%}. Student’s t-test was used for comparing the duration of apnoea. Results: The safe duration of apnoea was found to be significantly longer in patients receiving CPAP of 5 cm H2 O (Group P; n = 16) compared to the group receiving no CPAP (Group Z; n = 20), that is, 496.56 ± 71.68 s versus 273.00 ± 69.31 s (P < 0.001). Conclusion: The application of CPAP of 5 cm H 2 O using a Mapleson “A” circuit with a fixed positive end-expiratory pressure device during 5 min of pre-oxygenation with 100{\%} oxygen prior to the induction of anaesthesia provides a clearly longer duration of apnoea before clinically significant arterial desaturation occurs.",
author = "Sreejit, {Melveetil S.} and Venkateswaran Ramkumar",
year = "2015",
month = "1",
day = "1",
doi = "10.4103/0019-5049.154998",
language = "English",
volume = "59",
pages = "216--221",
journal = "Indian Journal of Anaesthesia",
issn = "0019-5049",
publisher = "Medknow Publications and Media Pvt. Ltd",
number = "4",

}

Effect of positive airway pressure during pre-oxygenation and induction of anaesthesia upon safe duration of apnoea. / Sreejit, Melveetil S.; Ramkumar, Venkateswaran.

In: Indian Journal of Anaesthesia, Vol. 59, No. 4, 01.01.2015, p. 216-221.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Effect of positive airway pressure during pre-oxygenation and induction of anaesthesia upon safe duration of apnoea

AU - Sreejit, Melveetil S.

AU - Ramkumar, Venkateswaran

PY - 2015/1/1

Y1 - 2015/1/1

N2 - Background and Aims: Induction of general anaesthesia per se as also the use of 100% oxygen during induction of anaesthesia, results in the development of atelectasis in dependent lung regions within minutes of anaesthetic induction. We aimed to assess the effect of application of a continuous positive airway pressure (CPAP) of 5 cm H 2 O during pre-oxygenation and induction of anaesthesia on the period of apnoea before the occurrence of clinically significant desaturation. Methods: In this prospective, randomised, and double-blind study, 40 patients posted for elective surgery were enrolled. Duration of apnoea was measured as the time from the administration of succinylcholine hydrochloride to the time when oxygen saturation fell to 93%. Student’s t-test was used for comparing the duration of apnoea. Results: The safe duration of apnoea was found to be significantly longer in patients receiving CPAP of 5 cm H2 O (Group P; n = 16) compared to the group receiving no CPAP (Group Z; n = 20), that is, 496.56 ± 71.68 s versus 273.00 ± 69.31 s (P < 0.001). Conclusion: The application of CPAP of 5 cm H 2 O using a Mapleson “A” circuit with a fixed positive end-expiratory pressure device during 5 min of pre-oxygenation with 100% oxygen prior to the induction of anaesthesia provides a clearly longer duration of apnoea before clinically significant arterial desaturation occurs.

AB - Background and Aims: Induction of general anaesthesia per se as also the use of 100% oxygen during induction of anaesthesia, results in the development of atelectasis in dependent lung regions within minutes of anaesthetic induction. We aimed to assess the effect of application of a continuous positive airway pressure (CPAP) of 5 cm H 2 O during pre-oxygenation and induction of anaesthesia on the period of apnoea before the occurrence of clinically significant desaturation. Methods: In this prospective, randomised, and double-blind study, 40 patients posted for elective surgery were enrolled. Duration of apnoea was measured as the time from the administration of succinylcholine hydrochloride to the time when oxygen saturation fell to 93%. Student’s t-test was used for comparing the duration of apnoea. Results: The safe duration of apnoea was found to be significantly longer in patients receiving CPAP of 5 cm H2 O (Group P; n = 16) compared to the group receiving no CPAP (Group Z; n = 20), that is, 496.56 ± 71.68 s versus 273.00 ± 69.31 s (P < 0.001). Conclusion: The application of CPAP of 5 cm H 2 O using a Mapleson “A” circuit with a fixed positive end-expiratory pressure device during 5 min of pre-oxygenation with 100% oxygen prior to the induction of anaesthesia provides a clearly longer duration of apnoea before clinically significant arterial desaturation occurs.

UR - http://www.scopus.com/inward/record.url?scp=84927518481&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84927518481&partnerID=8YFLogxK

U2 - 10.4103/0019-5049.154998

DO - 10.4103/0019-5049.154998

M3 - Article

VL - 59

SP - 216

EP - 221

JO - Indian Journal of Anaesthesia

JF - Indian Journal of Anaesthesia

SN - 0019-5049

IS - 4

ER -