Effect of unbalance in voltage supply on the detection of mixed air gap eccentricity in an induction motor by Motor Current Signature Analysis

R. L. Samaga, K. P. Vittal, J Vikas J

Research output: Chapter in Book/Report/Conference proceedingConference contribution

3 Citations (Scopus)

Abstract

Condition monitoring units are employed in industries to monitor the health of the machines continuously. Air gap eccentricity fault is one of the asymmetrical faults which can result in the machine failure. Motor Current Signature Analysis and Vibration Analysis are the two most popular methods used for eccentricity fault detection in the induction motor. In this paper, a study conducted on an induction motor to analyse the effect of supply voltage unbalance on the method of eccentricity fault detection by Motor Current Signature Analysis is presented. A dynamic model of the induction motor suffering from air gap eccentricity and has the capability to take unbalance supply voltage is developed and the results obtained by simulating this model are validated by the experiments conducted on an induction motor suffering from inclined mixed eccentricity and fed with unbalance voltage supply.

Original languageEnglish
Title of host publication2011 IEEE PES International Conference on Innovative Smart Grid Technologies-India, ISGT India 2011
Pages108-113
Number of pages6
DOIs
Publication statusPublished - 01-12-2011
Externally publishedYes
Event2011 IEEE PES International Conference on Innovative Smart Grid Technologies-India, ISGT India 2011 - Kollam, Kerala, India
Duration: 01-12-201103-12-2011

Conference

Conference2011 IEEE PES International Conference on Innovative Smart Grid Technologies-India, ISGT India 2011
CountryIndia
CityKollam, Kerala
Period01-12-1103-12-11

Fingerprint

Induction motors
Electric potential
Air
Fault detection
Condition monitoring
Vibration analysis
Dynamic models
Health
Industry
Experiments

All Science Journal Classification (ASJC) codes

  • Electrical and Electronic Engineering

Cite this

Samaga, R. L., Vittal, K. P., & Vikas J, J. (2011). Effect of unbalance in voltage supply on the detection of mixed air gap eccentricity in an induction motor by Motor Current Signature Analysis. In 2011 IEEE PES International Conference on Innovative Smart Grid Technologies-India, ISGT India 2011 (pp. 108-113). [6145365] https://doi.org/10.1109/ISET-India.2011.6145365
Samaga, R. L. ; Vittal, K. P. ; Vikas J, J. / Effect of unbalance in voltage supply on the detection of mixed air gap eccentricity in an induction motor by Motor Current Signature Analysis. 2011 IEEE PES International Conference on Innovative Smart Grid Technologies-India, ISGT India 2011. 2011. pp. 108-113
@inproceedings{b35f4afda80b44198041ba48818fdb20,
title = "Effect of unbalance in voltage supply on the detection of mixed air gap eccentricity in an induction motor by Motor Current Signature Analysis",
abstract = "Condition monitoring units are employed in industries to monitor the health of the machines continuously. Air gap eccentricity fault is one of the asymmetrical faults which can result in the machine failure. Motor Current Signature Analysis and Vibration Analysis are the two most popular methods used for eccentricity fault detection in the induction motor. In this paper, a study conducted on an induction motor to analyse the effect of supply voltage unbalance on the method of eccentricity fault detection by Motor Current Signature Analysis is presented. A dynamic model of the induction motor suffering from air gap eccentricity and has the capability to take unbalance supply voltage is developed and the results obtained by simulating this model are validated by the experiments conducted on an induction motor suffering from inclined mixed eccentricity and fed with unbalance voltage supply.",
author = "Samaga, {R. L.} and Vittal, {K. P.} and {Vikas J}, J",
year = "2011",
month = "12",
day = "1",
doi = "10.1109/ISET-India.2011.6145365",
language = "English",
isbn = "9781467303163",
pages = "108--113",
booktitle = "2011 IEEE PES International Conference on Innovative Smart Grid Technologies-India, ISGT India 2011",

}

Samaga, RL, Vittal, KP & Vikas J, J 2011, Effect of unbalance in voltage supply on the detection of mixed air gap eccentricity in an induction motor by Motor Current Signature Analysis. in 2011 IEEE PES International Conference on Innovative Smart Grid Technologies-India, ISGT India 2011., 6145365, pp. 108-113, 2011 IEEE PES International Conference on Innovative Smart Grid Technologies-India, ISGT India 2011, Kollam, Kerala, India, 01-12-11. https://doi.org/10.1109/ISET-India.2011.6145365

Effect of unbalance in voltage supply on the detection of mixed air gap eccentricity in an induction motor by Motor Current Signature Analysis. / Samaga, R. L.; Vittal, K. P.; Vikas J, J.

2011 IEEE PES International Conference on Innovative Smart Grid Technologies-India, ISGT India 2011. 2011. p. 108-113 6145365.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

TY - GEN

T1 - Effect of unbalance in voltage supply on the detection of mixed air gap eccentricity in an induction motor by Motor Current Signature Analysis

AU - Samaga, R. L.

AU - Vittal, K. P.

AU - Vikas J, J

PY - 2011/12/1

Y1 - 2011/12/1

N2 - Condition monitoring units are employed in industries to monitor the health of the machines continuously. Air gap eccentricity fault is one of the asymmetrical faults which can result in the machine failure. Motor Current Signature Analysis and Vibration Analysis are the two most popular methods used for eccentricity fault detection in the induction motor. In this paper, a study conducted on an induction motor to analyse the effect of supply voltage unbalance on the method of eccentricity fault detection by Motor Current Signature Analysis is presented. A dynamic model of the induction motor suffering from air gap eccentricity and has the capability to take unbalance supply voltage is developed and the results obtained by simulating this model are validated by the experiments conducted on an induction motor suffering from inclined mixed eccentricity and fed with unbalance voltage supply.

AB - Condition monitoring units are employed in industries to monitor the health of the machines continuously. Air gap eccentricity fault is one of the asymmetrical faults which can result in the machine failure. Motor Current Signature Analysis and Vibration Analysis are the two most popular methods used for eccentricity fault detection in the induction motor. In this paper, a study conducted on an induction motor to analyse the effect of supply voltage unbalance on the method of eccentricity fault detection by Motor Current Signature Analysis is presented. A dynamic model of the induction motor suffering from air gap eccentricity and has the capability to take unbalance supply voltage is developed and the results obtained by simulating this model are validated by the experiments conducted on an induction motor suffering from inclined mixed eccentricity and fed with unbalance voltage supply.

UR - http://www.scopus.com/inward/record.url?scp=84857315080&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84857315080&partnerID=8YFLogxK

U2 - 10.1109/ISET-India.2011.6145365

DO - 10.1109/ISET-India.2011.6145365

M3 - Conference contribution

AN - SCOPUS:84857315080

SN - 9781467303163

SP - 108

EP - 113

BT - 2011 IEEE PES International Conference on Innovative Smart Grid Technologies-India, ISGT India 2011

ER -

Samaga RL, Vittal KP, Vikas J J. Effect of unbalance in voltage supply on the detection of mixed air gap eccentricity in an induction motor by Motor Current Signature Analysis. In 2011 IEEE PES International Conference on Innovative Smart Grid Technologies-India, ISGT India 2011. 2011. p. 108-113. 6145365 https://doi.org/10.1109/ISET-India.2011.6145365