Emulated reactance and resistance by a sssc incorporating energy storage device

H. V. Gururaja Rao, Nagesh Prabhu, R. C. Mala

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

Static Synchronous series compensator without energy storage device can exchange only reactive power with the network and can operate in limited operating range in two quadrants only. When energy storage device is connected at the DC bus of SSSC (SSSC – ES), it can also exchange real power with the network. Operating range of SSSC will be much broader and it covers all the four quadrants. However, emulated reactance and resistance by SSSC – ES is likely to affect the performance of a distance protection system. This paper presents a detailed model of an SMIB system with SSSC – ES. Injected voltage by SSSC – ES in all the four quadrants of operation is presented. Impact of operation of SSSC – ES in different quadrants and various control strategies for SSSC – ES on impedance emulated by SSSC – ES during steady state condition and transient system disturbance is discussed.

Original languageEnglish
Pages (from-to)840-850
Number of pages11
JournalInternational Journal of Electrical and Computer Engineering
Volume9
Issue number2
DOIs
Publication statusPublished - 01-04-2019

Fingerprint

Energy storage
Reactive power
Electric potential

All Science Journal Classification (ASJC) codes

  • Computer Science(all)
  • Electrical and Electronic Engineering

Cite this

@article{94e1b101bab240ad93af58612289d06f,
title = "Emulated reactance and resistance by a sssc incorporating energy storage device",
abstract = "Static Synchronous series compensator without energy storage device can exchange only reactive power with the network and can operate in limited operating range in two quadrants only. When energy storage device is connected at the DC bus of SSSC (SSSC – ES), it can also exchange real power with the network. Operating range of SSSC will be much broader and it covers all the four quadrants. However, emulated reactance and resistance by SSSC – ES is likely to affect the performance of a distance protection system. This paper presents a detailed model of an SMIB system with SSSC – ES. Injected voltage by SSSC – ES in all the four quadrants of operation is presented. Impact of operation of SSSC – ES in different quadrants and various control strategies for SSSC – ES on impedance emulated by SSSC – ES during steady state condition and transient system disturbance is discussed.",
author = "{Gururaja Rao}, {H. V.} and Nagesh Prabhu and Mala, {R. C.}",
year = "2019",
month = "4",
day = "1",
doi = "10.11591/ijece.v9i2.pp.840-850",
language = "English",
volume = "9",
pages = "840--850",
journal = "International Journal of Electrical and Computer Engineering",
issn = "2088-8708",
publisher = "Institute of Advanced Engineering and Science (IAES)",
number = "2",

}

Emulated reactance and resistance by a sssc incorporating energy storage device. / Gururaja Rao, H. V.; Prabhu, Nagesh; Mala, R. C.

In: International Journal of Electrical and Computer Engineering, Vol. 9, No. 2, 01.04.2019, p. 840-850.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Emulated reactance and resistance by a sssc incorporating energy storage device

AU - Gururaja Rao, H. V.

AU - Prabhu, Nagesh

AU - Mala, R. C.

PY - 2019/4/1

Y1 - 2019/4/1

N2 - Static Synchronous series compensator without energy storage device can exchange only reactive power with the network and can operate in limited operating range in two quadrants only. When energy storage device is connected at the DC bus of SSSC (SSSC – ES), it can also exchange real power with the network. Operating range of SSSC will be much broader and it covers all the four quadrants. However, emulated reactance and resistance by SSSC – ES is likely to affect the performance of a distance protection system. This paper presents a detailed model of an SMIB system with SSSC – ES. Injected voltage by SSSC – ES in all the four quadrants of operation is presented. Impact of operation of SSSC – ES in different quadrants and various control strategies for SSSC – ES on impedance emulated by SSSC – ES during steady state condition and transient system disturbance is discussed.

AB - Static Synchronous series compensator without energy storage device can exchange only reactive power with the network and can operate in limited operating range in two quadrants only. When energy storage device is connected at the DC bus of SSSC (SSSC – ES), it can also exchange real power with the network. Operating range of SSSC will be much broader and it covers all the four quadrants. However, emulated reactance and resistance by SSSC – ES is likely to affect the performance of a distance protection system. This paper presents a detailed model of an SMIB system with SSSC – ES. Injected voltage by SSSC – ES in all the four quadrants of operation is presented. Impact of operation of SSSC – ES in different quadrants and various control strategies for SSSC – ES on impedance emulated by SSSC – ES during steady state condition and transient system disturbance is discussed.

UR - http://www.scopus.com/inward/record.url?scp=85059971985&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85059971985&partnerID=8YFLogxK

U2 - 10.11591/ijece.v9i2.pp.840-850

DO - 10.11591/ijece.v9i2.pp.840-850

M3 - Article

AN - SCOPUS:85059971985

VL - 9

SP - 840

EP - 850

JO - International Journal of Electrical and Computer Engineering

JF - International Journal of Electrical and Computer Engineering

SN - 2088-8708

IS - 2

ER -