Head strap double fluid level device

An innovative and user friendly design to record natural head position (NHP)

Lijo John, Nidhin Philip Jose, Siddarth Shetty

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

Head positions can be oriented in a standardized position when the patient stands upright and focusses his/her eyes into a point in infinity. This is the natural head position. This position offers the maximum reproducibility and correlates well with the clinical picture offered to the diagnostician. This article describes an innovative and user friendly method to record natural head position using the head strap double fluid level device, a design modified from the popular fluid level device by Showfety, Vig and Matteson.

Original languageEnglish
Pages (from-to)2-3
Number of pages2
JournalJournal of Clinical and Diagnostic Research
Volume9
Issue number1
DOIs
Publication statusPublished - 01-01-2015

Fingerprint

Head
Equipment and Supplies
Fluids
Equipment Design

All Science Journal Classification (ASJC) codes

  • Clinical Biochemistry

Cite this

@article{93b27827816e48e4b7000fa2d2444273,
title = "Head strap double fluid level device: An innovative and user friendly design to record natural head position (NHP)",
abstract = "Head positions can be oriented in a standardized position when the patient stands upright and focusses his/her eyes into a point in infinity. This is the natural head position. This position offers the maximum reproducibility and correlates well with the clinical picture offered to the diagnostician. This article describes an innovative and user friendly method to record natural head position using the head strap double fluid level device, a design modified from the popular fluid level device by Showfety, Vig and Matteson.",
author = "Lijo John and Jose, {Nidhin Philip} and Siddarth Shetty",
year = "2015",
month = "1",
day = "1",
doi = "10.7860/JCDR/2015/9357.5492",
language = "English",
volume = "9",
pages = "2--3",
journal = "Journal of Clinical and Diagnostic Research",
issn = "2249-782X",
publisher = "Journal of Clinical and Diagnostic Research",
number = "1",

}

Head strap double fluid level device : An innovative and user friendly design to record natural head position (NHP). / John, Lijo; Jose, Nidhin Philip; Shetty, Siddarth.

In: Journal of Clinical and Diagnostic Research, Vol. 9, No. 1, 01.01.2015, p. 2-3.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Head strap double fluid level device

T2 - An innovative and user friendly design to record natural head position (NHP)

AU - John, Lijo

AU - Jose, Nidhin Philip

AU - Shetty, Siddarth

PY - 2015/1/1

Y1 - 2015/1/1

N2 - Head positions can be oriented in a standardized position when the patient stands upright and focusses his/her eyes into a point in infinity. This is the natural head position. This position offers the maximum reproducibility and correlates well with the clinical picture offered to the diagnostician. This article describes an innovative and user friendly method to record natural head position using the head strap double fluid level device, a design modified from the popular fluid level device by Showfety, Vig and Matteson.

AB - Head positions can be oriented in a standardized position when the patient stands upright and focusses his/her eyes into a point in infinity. This is the natural head position. This position offers the maximum reproducibility and correlates well with the clinical picture offered to the diagnostician. This article describes an innovative and user friendly method to record natural head position using the head strap double fluid level device, a design modified from the popular fluid level device by Showfety, Vig and Matteson.

UR - http://www.scopus.com/inward/record.url?scp=84924860133&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84924860133&partnerID=8YFLogxK

U2 - 10.7860/JCDR/2015/9357.5492

DO - 10.7860/JCDR/2015/9357.5492

M3 - Article

VL - 9

SP - 2

EP - 3

JO - Journal of Clinical and Diagnostic Research

JF - Journal of Clinical and Diagnostic Research

SN - 2249-782X

IS - 1

ER -