Abstract

This paper describes the details of failure analysis of interference fitted assemblies. The assemblies were tested for their strength and noise generated during failure was recorded using a computer aided data acquisition system. Fast Fourier Transform (FFT) analysis was carried out to analyse the failure sound of assemblies using MATLAB. The results reveal that assemblies with lower interference produced less sound than the assemblies with higher interference during failure. Hence, where interference fit plays a critical role in mechanical assemblies, it is safer to mount a sensing device close to the assembly to detect the failure of assemblies. When the noise generated is beyond the safe limit, corrective action must be taken to detect the failure and initiate remedial measures, so that the accidents due to failure of interference fitted assemblies are eliminated.

Original languageEnglish
Pages (from-to)187-199
Number of pages13
JournalInternational Journal of Mechatronics and Manufacturing Systems
Volume2
Issue number1-2
DOIs
Publication statusPublished - 01-04-2009

Fingerprint

Failure analysis
Acoustic waves
Fast Fourier transforms
MATLAB
Data acquisition
Accidents

All Science Journal Classification (ASJC) codes

  • Electrical and Electronic Engineering
  • Mechanical Engineering

Cite this

@article{840435486e7e48d9a38841147831d51c,
title = "Interference fitted assemblies: A failure analysis",
abstract = "This paper describes the details of failure analysis of interference fitted assemblies. The assemblies were tested for their strength and noise generated during failure was recorded using a computer aided data acquisition system. Fast Fourier Transform (FFT) analysis was carried out to analyse the failure sound of assemblies using MATLAB. The results reveal that assemblies with lower interference produced less sound than the assemblies with higher interference during failure. Hence, where interference fit plays a critical role in mechanical assemblies, it is safer to mount a sensing device close to the assembly to detect the failure of assemblies. When the noise generated is beyond the safe limit, corrective action must be taken to detect the failure and initiate remedial measures, so that the accidents due to failure of interference fitted assemblies are eliminated.",
author = "Irappa Sogalad and Udupa, {N. G Subramanya}",
year = "2009",
month = "4",
day = "1",
doi = "10.1504/IJMMS.2009.024355",
language = "English",
volume = "2",
pages = "187--199",
journal = "International Journal of Mechatronics and Manufacturing Systems",
issn = "1753-1039",
publisher = "Inderscience Enterprises Ltd",
number = "1-2",

}

Interference fitted assemblies : A failure analysis. / Sogalad, Irappa; Udupa, N. G Subramanya.

In: International Journal of Mechatronics and Manufacturing Systems, Vol. 2, No. 1-2, 01.04.2009, p. 187-199.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Interference fitted assemblies

T2 - A failure analysis

AU - Sogalad, Irappa

AU - Udupa, N. G Subramanya

PY - 2009/4/1

Y1 - 2009/4/1

N2 - This paper describes the details of failure analysis of interference fitted assemblies. The assemblies were tested for their strength and noise generated during failure was recorded using a computer aided data acquisition system. Fast Fourier Transform (FFT) analysis was carried out to analyse the failure sound of assemblies using MATLAB. The results reveal that assemblies with lower interference produced less sound than the assemblies with higher interference during failure. Hence, where interference fit plays a critical role in mechanical assemblies, it is safer to mount a sensing device close to the assembly to detect the failure of assemblies. When the noise generated is beyond the safe limit, corrective action must be taken to detect the failure and initiate remedial measures, so that the accidents due to failure of interference fitted assemblies are eliminated.

AB - This paper describes the details of failure analysis of interference fitted assemblies. The assemblies were tested for their strength and noise generated during failure was recorded using a computer aided data acquisition system. Fast Fourier Transform (FFT) analysis was carried out to analyse the failure sound of assemblies using MATLAB. The results reveal that assemblies with lower interference produced less sound than the assemblies with higher interference during failure. Hence, where interference fit plays a critical role in mechanical assemblies, it is safer to mount a sensing device close to the assembly to detect the failure of assemblies. When the noise generated is beyond the safe limit, corrective action must be taken to detect the failure and initiate remedial measures, so that the accidents due to failure of interference fitted assemblies are eliminated.

UR - http://www.scopus.com/inward/record.url?scp=66149173691&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=66149173691&partnerID=8YFLogxK

U2 - 10.1504/IJMMS.2009.024355

DO - 10.1504/IJMMS.2009.024355

M3 - Article

VL - 2

SP - 187

EP - 199

JO - International Journal of Mechatronics and Manufacturing Systems

JF - International Journal of Mechatronics and Manufacturing Systems

SN - 1753-1039

IS - 1-2

ER -