Laryngospasm during extubation. Can nasogastric tube be the culprit?

Nandeesha Nanjegowda, Shashikiran Umakanth, Vivekanand Undrakonda

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

Nasogastric tube insertion is a common clinical procedure carried out both by doctors and other paramedical personnel. Misplacement of the nasogastric tube into the tracheobronchial tree is not uncommon. It can easily be detected in awake patients with intact cough reflex. Insertion of the nasogastric tube under general endotracheal anaesthesia can be difficult and when the misplacement is not promptly detected can result in unusual and disastrous complications. Laryngospasm is not uncommon in anaesthetic practice; however, reports of recurrent laryngospasm are very sparse. We report a case of misplaced nasogastric tube causing recurrent laryngospasm.

Original languageEnglish
JournalBMJ Case Reports
DOIs
Publication statusPublished - 19-06-2013

Fingerprint

Laryngismus
Endotracheal Anesthesia
Allied Health Personnel
Cough
General Anesthesia
Reflex
Anesthetics

All Science Journal Classification (ASJC) codes

  • Medicine(all)

Cite this

@article{5f0128f14e7f4dc59271d65896c52747,
title = "Laryngospasm during extubation. Can nasogastric tube be the culprit?",
abstract = "Nasogastric tube insertion is a common clinical procedure carried out both by doctors and other paramedical personnel. Misplacement of the nasogastric tube into the tracheobronchial tree is not uncommon. It can easily be detected in awake patients with intact cough reflex. Insertion of the nasogastric tube under general endotracheal anaesthesia can be difficult and when the misplacement is not promptly detected can result in unusual and disastrous complications. Laryngospasm is not uncommon in anaesthetic practice; however, reports of recurrent laryngospasm are very sparse. We report a case of misplaced nasogastric tube causing recurrent laryngospasm.",
author = "Nandeesha Nanjegowda and Shashikiran Umakanth and Vivekanand Undrakonda",
year = "2013",
month = "6",
day = "19",
doi = "10.1136/bcr-2013-009645",
language = "English",
journal = "BMJ Case Reports",
issn = "1757-790X",
publisher = "BMJ Publishing Group",

}

Laryngospasm during extubation. Can nasogastric tube be the culprit? / Nanjegowda, Nandeesha; Umakanth, Shashikiran; Undrakonda, Vivekanand.

In: BMJ Case Reports, 19.06.2013.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Laryngospasm during extubation. Can nasogastric tube be the culprit?

AU - Nanjegowda, Nandeesha

AU - Umakanth, Shashikiran

AU - Undrakonda, Vivekanand

PY - 2013/6/19

Y1 - 2013/6/19

N2 - Nasogastric tube insertion is a common clinical procedure carried out both by doctors and other paramedical personnel. Misplacement of the nasogastric tube into the tracheobronchial tree is not uncommon. It can easily be detected in awake patients with intact cough reflex. Insertion of the nasogastric tube under general endotracheal anaesthesia can be difficult and when the misplacement is not promptly detected can result in unusual and disastrous complications. Laryngospasm is not uncommon in anaesthetic practice; however, reports of recurrent laryngospasm are very sparse. We report a case of misplaced nasogastric tube causing recurrent laryngospasm.

AB - Nasogastric tube insertion is a common clinical procedure carried out both by doctors and other paramedical personnel. Misplacement of the nasogastric tube into the tracheobronchial tree is not uncommon. It can easily be detected in awake patients with intact cough reflex. Insertion of the nasogastric tube under general endotracheal anaesthesia can be difficult and when the misplacement is not promptly detected can result in unusual and disastrous complications. Laryngospasm is not uncommon in anaesthetic practice; however, reports of recurrent laryngospasm are very sparse. We report a case of misplaced nasogastric tube causing recurrent laryngospasm.

UR - http://www.scopus.com/inward/record.url?scp=84880121635&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84880121635&partnerID=8YFLogxK

U2 - 10.1136/bcr-2013-009645

DO - 10.1136/bcr-2013-009645

M3 - Article

JO - BMJ Case Reports

JF - BMJ Case Reports

SN - 1757-790X