Measurement of flow using bend sensor

C. R. Srinivasan, Susobhit Sen, Anjan Kumar, Chenchu Saibabu

Research output: Contribution to conferencePaper

3 Citations (Scopus)

Abstract

This paper presents an innovative design and accurate approach to the measurement of flow rate for moderate flow applications. It also deduces linear relationship between flow rate and the change in resistance of the bend sensor used in the setup. The sensor apparatus is very simple to calibrate and install which is a fixed beam cantilever system with one moving end which would give a digital output. The displacement values of free end of the sensor are analysed using ANSYS Finite Element Analysis software.

Original languageEnglish
Pages27-30
Number of pages4
DOIs
Publication statusPublished - 01-01-2014
Event2014 International Conference on Advances in Energy Conversion Technologies - Intelligent Energy Management: Technologies and Challenges, ICAECT 2014 - Manipal, India
Duration: 23-01-201425-01-2014

Conference

Conference2014 International Conference on Advances in Energy Conversion Technologies - Intelligent Energy Management: Technologies and Challenges, ICAECT 2014
CountryIndia
CityManipal
Period23-01-1425-01-14

Fingerprint

Sensors
Flow rate
Cantilever beams
Finite element method

All Science Journal Classification (ASJC) codes

  • Energy Engineering and Power Technology
  • Fuel Technology

Cite this

Srinivasan, C. R., Sen, S., Kumar, A., & Saibabu, C. (2014). Measurement of flow using bend sensor. 27-30. Paper presented at 2014 International Conference on Advances in Energy Conversion Technologies - Intelligent Energy Management: Technologies and Challenges, ICAECT 2014, Manipal, India. https://doi.org/10.1109/ICAECT.2014.6757056
Srinivasan, C. R. ; Sen, Susobhit ; Kumar, Anjan ; Saibabu, Chenchu. / Measurement of flow using bend sensor. Paper presented at 2014 International Conference on Advances in Energy Conversion Technologies - Intelligent Energy Management: Technologies and Challenges, ICAECT 2014, Manipal, India.4 p.
@conference{497dba2211704233b612b9ffb1ca985c,
title = "Measurement of flow using bend sensor",
abstract = "This paper presents an innovative design and accurate approach to the measurement of flow rate for moderate flow applications. It also deduces linear relationship between flow rate and the change in resistance of the bend sensor used in the setup. The sensor apparatus is very simple to calibrate and install which is a fixed beam cantilever system with one moving end which would give a digital output. The displacement values of free end of the sensor are analysed using ANSYS Finite Element Analysis software.",
author = "Srinivasan, {C. R.} and Susobhit Sen and Anjan Kumar and Chenchu Saibabu",
year = "2014",
month = "1",
day = "1",
doi = "10.1109/ICAECT.2014.6757056",
language = "English",
pages = "27--30",
note = "2014 International Conference on Advances in Energy Conversion Technologies - Intelligent Energy Management: Technologies and Challenges, ICAECT 2014 ; Conference date: 23-01-2014 Through 25-01-2014",

}

Srinivasan, CR, Sen, S, Kumar, A & Saibabu, C 2014, 'Measurement of flow using bend sensor' Paper presented at 2014 International Conference on Advances in Energy Conversion Technologies - Intelligent Energy Management: Technologies and Challenges, ICAECT 2014, Manipal, India, 23-01-14 - 25-01-14, pp. 27-30. https://doi.org/10.1109/ICAECT.2014.6757056

Measurement of flow using bend sensor. / Srinivasan, C. R.; Sen, Susobhit; Kumar, Anjan; Saibabu, Chenchu.

2014. 27-30 Paper presented at 2014 International Conference on Advances in Energy Conversion Technologies - Intelligent Energy Management: Technologies and Challenges, ICAECT 2014, Manipal, India.

Research output: Contribution to conferencePaper

TY - CONF

T1 - Measurement of flow using bend sensor

AU - Srinivasan, C. R.

AU - Sen, Susobhit

AU - Kumar, Anjan

AU - Saibabu, Chenchu

PY - 2014/1/1

Y1 - 2014/1/1

N2 - This paper presents an innovative design and accurate approach to the measurement of flow rate for moderate flow applications. It also deduces linear relationship between flow rate and the change in resistance of the bend sensor used in the setup. The sensor apparatus is very simple to calibrate and install which is a fixed beam cantilever system with one moving end which would give a digital output. The displacement values of free end of the sensor are analysed using ANSYS Finite Element Analysis software.

AB - This paper presents an innovative design and accurate approach to the measurement of flow rate for moderate flow applications. It also deduces linear relationship between flow rate and the change in resistance of the bend sensor used in the setup. The sensor apparatus is very simple to calibrate and install which is a fixed beam cantilever system with one moving end which would give a digital output. The displacement values of free end of the sensor are analysed using ANSYS Finite Element Analysis software.

UR - http://www.scopus.com/inward/record.url?scp=84897530264&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84897530264&partnerID=8YFLogxK

U2 - 10.1109/ICAECT.2014.6757056

DO - 10.1109/ICAECT.2014.6757056

M3 - Paper

AN - SCOPUS:84897530264

SP - 27

EP - 30

ER -

Srinivasan CR, Sen S, Kumar A, Saibabu C. Measurement of flow using bend sensor. 2014. Paper presented at 2014 International Conference on Advances in Energy Conversion Technologies - Intelligent Energy Management: Technologies and Challenges, ICAECT 2014, Manipal, India. https://doi.org/10.1109/ICAECT.2014.6757056