Microwave histoprocessing versus conventional histoprocessing

Alka Mathai, Ramadas Naik, Muktha Pai, Sharada Rai, Poornima Baliga

Research output: Contribution to journalArticle

13 Citations (Scopus)

Abstract

The aim of the study is to compare the histologic quality of the microwave histoprocessing with that of conventional method and to determine its positive impact on turnaround times and reduction of costs of tissue processing. One hundred and eighty-five paired tissue sections from different organs were taken. Each tissue sections were of size of 15 mm x 10 mm x 3 mm and divided into two; one set as experimental group and the other as control group. The tissues in the experimental group were further divided into six groups and processed by vacuum-microwave method according to six protocols from I to VI. Other tissues in the control group were processed by the conventional method and compared. Overall, the quality of microscopic tissue from both the methods was identical. Microwave processing shortened the time of processing without compromising the overall quality of the histologic section and was cost-effective.

Original languageEnglish
Pages (from-to)12-16
Number of pages5
JournalIndian Journal of Pathology and Microbiology
Volume51
Issue number1
DOIs
Publication statusPublished - 01-01-2008

Fingerprint

Microwaves
Costs and Cost Analysis
Control Groups
Vacuum

All Science Journal Classification (ASJC) codes

  • Pathology and Forensic Medicine
  • Microbiology (medical)

Cite this

@article{eb362245b5174441be81886ada8a2c7f,
title = "Microwave histoprocessing versus conventional histoprocessing",
abstract = "The aim of the study is to compare the histologic quality of the microwave histoprocessing with that of conventional method and to determine its positive impact on turnaround times and reduction of costs of tissue processing. One hundred and eighty-five paired tissue sections from different organs were taken. Each tissue sections were of size of 15 mm x 10 mm x 3 mm and divided into two; one set as experimental group and the other as control group. The tissues in the experimental group were further divided into six groups and processed by vacuum-microwave method according to six protocols from I to VI. Other tissues in the control group were processed by the conventional method and compared. Overall, the quality of microscopic tissue from both the methods was identical. Microwave processing shortened the time of processing without compromising the overall quality of the histologic section and was cost-effective.",
author = "Alka Mathai and Ramadas Naik and Muktha Pai and Sharada Rai and Poornima Baliga",
year = "2008",
month = "1",
day = "1",
doi = "10.4103/0377-4929.40383",
language = "English",
volume = "51",
pages = "12--16",
journal = "Indian Journal of Pathology and Microbiology",
issn = "0377-4929",
publisher = "Medknow Publications and Media Pvt. Ltd",
number = "1",

}

Microwave histoprocessing versus conventional histoprocessing. / Mathai, Alka; Naik, Ramadas; Pai, Muktha; Rai, Sharada; Baliga, Poornima.

In: Indian Journal of Pathology and Microbiology, Vol. 51, No. 1, 01.01.2008, p. 12-16.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Microwave histoprocessing versus conventional histoprocessing

AU - Mathai, Alka

AU - Naik, Ramadas

AU - Pai, Muktha

AU - Rai, Sharada

AU - Baliga, Poornima

PY - 2008/1/1

Y1 - 2008/1/1

N2 - The aim of the study is to compare the histologic quality of the microwave histoprocessing with that of conventional method and to determine its positive impact on turnaround times and reduction of costs of tissue processing. One hundred and eighty-five paired tissue sections from different organs were taken. Each tissue sections were of size of 15 mm x 10 mm x 3 mm and divided into two; one set as experimental group and the other as control group. The tissues in the experimental group were further divided into six groups and processed by vacuum-microwave method according to six protocols from I to VI. Other tissues in the control group were processed by the conventional method and compared. Overall, the quality of microscopic tissue from both the methods was identical. Microwave processing shortened the time of processing without compromising the overall quality of the histologic section and was cost-effective.

AB - The aim of the study is to compare the histologic quality of the microwave histoprocessing with that of conventional method and to determine its positive impact on turnaround times and reduction of costs of tissue processing. One hundred and eighty-five paired tissue sections from different organs were taken. Each tissue sections were of size of 15 mm x 10 mm x 3 mm and divided into two; one set as experimental group and the other as control group. The tissues in the experimental group were further divided into six groups and processed by vacuum-microwave method according to six protocols from I to VI. Other tissues in the control group were processed by the conventional method and compared. Overall, the quality of microscopic tissue from both the methods was identical. Microwave processing shortened the time of processing without compromising the overall quality of the histologic section and was cost-effective.

UR - http://www.scopus.com/inward/record.url?scp=43449134099&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=43449134099&partnerID=8YFLogxK

U2 - 10.4103/0377-4929.40383

DO - 10.4103/0377-4929.40383

M3 - Article

C2 - 18417842

AN - SCOPUS:43449134099

VL - 51

SP - 12

EP - 16

JO - Indian Journal of Pathology and Microbiology

JF - Indian Journal of Pathology and Microbiology

SN - 0377-4929

IS - 1

ER -