Novel liquid chromatographic method for simultaneous estimation of pioglitazone and glimepiride in rat plasma by solid phase extraction: Application to preclinical pharmacokinetic studies

Prashant B. Musmade, Kranti B. Talole, Praful B. Deshpande, Arumugam Karthik, Shriram M. Pathak, Sureshwar Pandey, Nayanabhirama Udupa

Research output: Contribution to journalArticle

6 Citations (Scopus)

Abstract

The need for a reliable bioanalytical method is of primary importance during preclinical studies. The aim of the present study was simultaneous determination of pioglitazone (CAS 111025-46-8) (PIO) and glimepiride (CAS 93479-97-1) (GLM) in plasma of rats. A high-performance liquid chromatographic method has been developed and validated using C18 column and UV detector. A mobile phase composed of acetonitrile and ammonium acetate buffer pH 4.5 in the ratio of 55:45%. The plasma samples clean-up was carried out using solid phase cartridges. The method was in the linear range of 50-8000 ng/mL for PIO and 50-2000 ng/mL for GLM. The coefficient of regression was found to be ≥0.99. Precision and accuracy were within the acceptable limits, as indicated by relative standard deviation varying from 1.5 to 6.1% for PIO and 3.1 to 7.0% for GLM whereas the accuracy ranged from 97.0 to 106.4% for PIO and 96.5 to 106.4% for GLM. The mean extraction recovery was found to be 90.2 ± 4.5, 76.8 ± 2.8 and 85.2 ± 5.2% for PIO, GLM and internal standard, respectively. Moreover, PIO and GLM were stable in plasma, up to 30 days of storage at -70 °C and after being subjected to bench top, autosampler, and three freeze-thaw cycles. The developed method was applied for preclinical pharmacokinetic studies.

Original languageEnglish
Pages (from-to)23-31
Number of pages9
JournalArzneimittel-Forschung/Drug Research
Volume61
Issue number1
Publication statusPublished - 2011

Fingerprint

pioglitazone
glimepiride
Solid Phase Extraction
Pharmacokinetics
Buffers

All Science Journal Classification (ASJC) codes

  • Drug Discovery

Cite this

Musmade, Prashant B. ; Talole, Kranti B. ; Deshpande, Praful B. ; Karthik, Arumugam ; Pathak, Shriram M. ; Pandey, Sureshwar ; Udupa, Nayanabhirama. / Novel liquid chromatographic method for simultaneous estimation of pioglitazone and glimepiride in rat plasma by solid phase extraction: Application to preclinical pharmacokinetic studies. In: Arzneimittel-Forschung/Drug Research. 2011 ; Vol. 61, No. 1. pp. 23-31.
@article{713994e702804e9eab54e769b567d1c5,
title = "Novel liquid chromatographic method for simultaneous estimation of pioglitazone and glimepiride in rat plasma by solid phase extraction: Application to preclinical pharmacokinetic studies",
abstract = "The need for a reliable bioanalytical method is of primary importance during preclinical studies. The aim of the present study was simultaneous determination of pioglitazone (CAS 111025-46-8) (PIO) and glimepiride (CAS 93479-97-1) (GLM) in plasma of rats. A high-performance liquid chromatographic method has been developed and validated using C18 column and UV detector. A mobile phase composed of acetonitrile and ammonium acetate buffer pH 4.5 in the ratio of 55:45{\%}. The plasma samples clean-up was carried out using solid phase cartridges. The method was in the linear range of 50-8000 ng/mL for PIO and 50-2000 ng/mL for GLM. The coefficient of regression was found to be ≥0.99. Precision and accuracy were within the acceptable limits, as indicated by relative standard deviation varying from 1.5 to 6.1{\%} for PIO and 3.1 to 7.0{\%} for GLM whereas the accuracy ranged from 97.0 to 106.4{\%} for PIO and 96.5 to 106.4{\%} for GLM. The mean extraction recovery was found to be 90.2 ± 4.5, 76.8 ± 2.8 and 85.2 ± 5.2{\%} for PIO, GLM and internal standard, respectively. Moreover, PIO and GLM were stable in plasma, up to 30 days of storage at -70 °C and after being subjected to bench top, autosampler, and three freeze-thaw cycles. The developed method was applied for preclinical pharmacokinetic studies.",
author = "Musmade, {Prashant B.} and Talole, {Kranti B.} and Deshpande, {Praful B.} and Arumugam Karthik and Pathak, {Shriram M.} and Sureshwar Pandey and Nayanabhirama Udupa",
note = "cited By 5",
year = "2011",
language = "English",
volume = "61",
pages = "23--31",
journal = "Drug Research",
issn = "2194-9379",
publisher = "Thieme",
number = "1",

}

Novel liquid chromatographic method for simultaneous estimation of pioglitazone and glimepiride in rat plasma by solid phase extraction: Application to preclinical pharmacokinetic studies. / Musmade, Prashant B.; Talole, Kranti B.; Deshpande, Praful B.; Karthik, Arumugam; Pathak, Shriram M.; Pandey, Sureshwar; Udupa, Nayanabhirama.

In: Arzneimittel-Forschung/Drug Research, Vol. 61, No. 1, 2011, p. 23-31.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Novel liquid chromatographic method for simultaneous estimation of pioglitazone and glimepiride in rat plasma by solid phase extraction: Application to preclinical pharmacokinetic studies

AU - Musmade, Prashant B.

AU - Talole, Kranti B.

AU - Deshpande, Praful B.

AU - Karthik, Arumugam

AU - Pathak, Shriram M.

AU - Pandey, Sureshwar

AU - Udupa, Nayanabhirama

N1 - cited By 5

PY - 2011

Y1 - 2011

N2 - The need for a reliable bioanalytical method is of primary importance during preclinical studies. The aim of the present study was simultaneous determination of pioglitazone (CAS 111025-46-8) (PIO) and glimepiride (CAS 93479-97-1) (GLM) in plasma of rats. A high-performance liquid chromatographic method has been developed and validated using C18 column and UV detector. A mobile phase composed of acetonitrile and ammonium acetate buffer pH 4.5 in the ratio of 55:45%. The plasma samples clean-up was carried out using solid phase cartridges. The method was in the linear range of 50-8000 ng/mL for PIO and 50-2000 ng/mL for GLM. The coefficient of regression was found to be ≥0.99. Precision and accuracy were within the acceptable limits, as indicated by relative standard deviation varying from 1.5 to 6.1% for PIO and 3.1 to 7.0% for GLM whereas the accuracy ranged from 97.0 to 106.4% for PIO and 96.5 to 106.4% for GLM. The mean extraction recovery was found to be 90.2 ± 4.5, 76.8 ± 2.8 and 85.2 ± 5.2% for PIO, GLM and internal standard, respectively. Moreover, PIO and GLM were stable in plasma, up to 30 days of storage at -70 °C and after being subjected to bench top, autosampler, and three freeze-thaw cycles. The developed method was applied for preclinical pharmacokinetic studies.

AB - The need for a reliable bioanalytical method is of primary importance during preclinical studies. The aim of the present study was simultaneous determination of pioglitazone (CAS 111025-46-8) (PIO) and glimepiride (CAS 93479-97-1) (GLM) in plasma of rats. A high-performance liquid chromatographic method has been developed and validated using C18 column and UV detector. A mobile phase composed of acetonitrile and ammonium acetate buffer pH 4.5 in the ratio of 55:45%. The plasma samples clean-up was carried out using solid phase cartridges. The method was in the linear range of 50-8000 ng/mL for PIO and 50-2000 ng/mL for GLM. The coefficient of regression was found to be ≥0.99. Precision and accuracy were within the acceptable limits, as indicated by relative standard deviation varying from 1.5 to 6.1% for PIO and 3.1 to 7.0% for GLM whereas the accuracy ranged from 97.0 to 106.4% for PIO and 96.5 to 106.4% for GLM. The mean extraction recovery was found to be 90.2 ± 4.5, 76.8 ± 2.8 and 85.2 ± 5.2% for PIO, GLM and internal standard, respectively. Moreover, PIO and GLM were stable in plasma, up to 30 days of storage at -70 °C and after being subjected to bench top, autosampler, and three freeze-thaw cycles. The developed method was applied for preclinical pharmacokinetic studies.

UR - http://www.scopus.com/inward/record.url?scp=79951938467&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79951938467&partnerID=8YFLogxK

M3 - Article

VL - 61

SP - 23

EP - 31

JO - Drug Research

JF - Drug Research

SN - 2194-9379

IS - 1

ER -