Options in orbital floor reconstruction in blowout fractures: a review of ten cases

Premalatha Shetty, G. Senthil Kumar, Mohan Baliga, Nakul Uppal

Research output: Contribution to journalArticle

8 Citations (Scopus)

Abstract

Objective: The purpose of this case series was to assess the aesthetic and functional outcome of orbital floor reconstruction performed with calvarial bone graft, titanium mesh or prolene mesh. Methods: Ten cases of orbital blowout fractures treated at our centre from October 2006 to July 2008 were considered for this study. Clinical examination, patient satisfaction and radiographic investigations were used to assess repaired fractures. Results: Prolene mesh was used in four cases, titanium mesh was used in four cases and calvarial graft used in two cases. Nine patients had significant improvement in their esthetic appearance. Symmetry was restored in all cases. All ten cases had a noticeable improvement in the function. Of total ten cases six had diplopia, three recovered completely during the six months after the surgery. Three cases showed improvement later. All ten cases with enopthalmos recovered completely. Of the nine patients with infraorbital numbness, all recovered completely during the six months following surgery. One patient where the reconstruction was done with calvarial bone graft showed mild discrepancy in the ocular level. Conclusion: For small, linear defects measuring less than 2cm with enopthalmos and restricted ocular movements, prolene mesh (four cases) was used. For larger defects and impure blowout fractures involving the infraorbital rim, calvarial graft (two cases) or titanium mesh (four cases) was used. The outcome of surgery with all three materials was satisfactory. No postoperative complications were seen except for mild hypoglobus in a case reconstructed with calvarial graft. All three materials, calvarial graft, titanium mesh, prolene mesh, have the potential to be useful reconstructive materials in orbital floor blowout fractures.

Original languageEnglish
Pages (from-to)137-140
Number of pages4
JournalJournal of Maxillofacial and Oral Surgery
Volume8
Issue number2
DOIs
Publication statusPublished - 01-06-2009

Fingerprint

Polypropylenes
Titanium
Transplants
Esthetics
Orbital Fractures
Bone and Bones
Diplopia
Hypesthesia
Eye Movements
Patient Satisfaction

All Science Journal Classification (ASJC) codes

  • Oral Surgery
  • Surgery
  • Otorhinolaryngology

Cite this

Shetty, Premalatha ; Senthil Kumar, G. ; Baliga, Mohan ; Uppal, Nakul. / Options in orbital floor reconstruction in blowout fractures : a review of ten cases. In: Journal of Maxillofacial and Oral Surgery. 2009 ; Vol. 8, No. 2. pp. 137-140.
@article{5fd6e0ccdc8443dbbce4fab559a1d307,
title = "Options in orbital floor reconstruction in blowout fractures: a review of ten cases",
abstract = "Objective: The purpose of this case series was to assess the aesthetic and functional outcome of orbital floor reconstruction performed with calvarial bone graft, titanium mesh or prolene mesh. Methods: Ten cases of orbital blowout fractures treated at our centre from October 2006 to July 2008 were considered for this study. Clinical examination, patient satisfaction and radiographic investigations were used to assess repaired fractures. Results: Prolene mesh was used in four cases, titanium mesh was used in four cases and calvarial graft used in two cases. Nine patients had significant improvement in their esthetic appearance. Symmetry was restored in all cases. All ten cases had a noticeable improvement in the function. Of total ten cases six had diplopia, three recovered completely during the six months after the surgery. Three cases showed improvement later. All ten cases with enopthalmos recovered completely. Of the nine patients with infraorbital numbness, all recovered completely during the six months following surgery. One patient where the reconstruction was done with calvarial bone graft showed mild discrepancy in the ocular level. Conclusion: For small, linear defects measuring less than 2cm with enopthalmos and restricted ocular movements, prolene mesh (four cases) was used. For larger defects and impure blowout fractures involving the infraorbital rim, calvarial graft (two cases) or titanium mesh (four cases) was used. The outcome of surgery with all three materials was satisfactory. No postoperative complications were seen except for mild hypoglobus in a case reconstructed with calvarial graft. All three materials, calvarial graft, titanium mesh, prolene mesh, have the potential to be useful reconstructive materials in orbital floor blowout fractures.",
author = "Premalatha Shetty and {Senthil Kumar}, G. and Mohan Baliga and Nakul Uppal",
year = "2009",
month = "6",
day = "1",
doi = "10.1007/s12663-009-0034-7",
language = "English",
volume = "8",
pages = "137--140",
journal = "Journal of Maxillofacial and Oral Surgery",
issn = "0972-8279",
number = "2",

}

Options in orbital floor reconstruction in blowout fractures : a review of ten cases. / Shetty, Premalatha; Senthil Kumar, G.; Baliga, Mohan; Uppal, Nakul.

In: Journal of Maxillofacial and Oral Surgery, Vol. 8, No. 2, 01.06.2009, p. 137-140.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Options in orbital floor reconstruction in blowout fractures

T2 - a review of ten cases

AU - Shetty, Premalatha

AU - Senthil Kumar, G.

AU - Baliga, Mohan

AU - Uppal, Nakul

PY - 2009/6/1

Y1 - 2009/6/1

N2 - Objective: The purpose of this case series was to assess the aesthetic and functional outcome of orbital floor reconstruction performed with calvarial bone graft, titanium mesh or prolene mesh. Methods: Ten cases of orbital blowout fractures treated at our centre from October 2006 to July 2008 were considered for this study. Clinical examination, patient satisfaction and radiographic investigations were used to assess repaired fractures. Results: Prolene mesh was used in four cases, titanium mesh was used in four cases and calvarial graft used in two cases. Nine patients had significant improvement in their esthetic appearance. Symmetry was restored in all cases. All ten cases had a noticeable improvement in the function. Of total ten cases six had diplopia, three recovered completely during the six months after the surgery. Three cases showed improvement later. All ten cases with enopthalmos recovered completely. Of the nine patients with infraorbital numbness, all recovered completely during the six months following surgery. One patient where the reconstruction was done with calvarial bone graft showed mild discrepancy in the ocular level. Conclusion: For small, linear defects measuring less than 2cm with enopthalmos and restricted ocular movements, prolene mesh (four cases) was used. For larger defects and impure blowout fractures involving the infraorbital rim, calvarial graft (two cases) or titanium mesh (four cases) was used. The outcome of surgery with all three materials was satisfactory. No postoperative complications were seen except for mild hypoglobus in a case reconstructed with calvarial graft. All three materials, calvarial graft, titanium mesh, prolene mesh, have the potential to be useful reconstructive materials in orbital floor blowout fractures.

AB - Objective: The purpose of this case series was to assess the aesthetic and functional outcome of orbital floor reconstruction performed with calvarial bone graft, titanium mesh or prolene mesh. Methods: Ten cases of orbital blowout fractures treated at our centre from October 2006 to July 2008 were considered for this study. Clinical examination, patient satisfaction and radiographic investigations were used to assess repaired fractures. Results: Prolene mesh was used in four cases, titanium mesh was used in four cases and calvarial graft used in two cases. Nine patients had significant improvement in their esthetic appearance. Symmetry was restored in all cases. All ten cases had a noticeable improvement in the function. Of total ten cases six had diplopia, three recovered completely during the six months after the surgery. Three cases showed improvement later. All ten cases with enopthalmos recovered completely. Of the nine patients with infraorbital numbness, all recovered completely during the six months following surgery. One patient where the reconstruction was done with calvarial bone graft showed mild discrepancy in the ocular level. Conclusion: For small, linear defects measuring less than 2cm with enopthalmos and restricted ocular movements, prolene mesh (four cases) was used. For larger defects and impure blowout fractures involving the infraorbital rim, calvarial graft (two cases) or titanium mesh (four cases) was used. The outcome of surgery with all three materials was satisfactory. No postoperative complications were seen except for mild hypoglobus in a case reconstructed with calvarial graft. All three materials, calvarial graft, titanium mesh, prolene mesh, have the potential to be useful reconstructive materials in orbital floor blowout fractures.

UR - http://www.scopus.com/inward/record.url?scp=78650676779&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=78650676779&partnerID=8YFLogxK

U2 - 10.1007/s12663-009-0034-7

DO - 10.1007/s12663-009-0034-7

M3 - Article

AN - SCOPUS:78650676779

VL - 8

SP - 137

EP - 140

JO - Journal of Maxillofacial and Oral Surgery

JF - Journal of Maxillofacial and Oral Surgery

SN - 0972-8279

IS - 2

ER -