Performance analysis of centrifugal pumps subjected to voltage variation and unbalance

P. Giridhar Kini, Ramesh C. Bansal, R. S. Aithal

Research output: Contribution to journalArticle

23 Citations (Scopus)

Abstract

Frequent variation of single-phase loads on power system networks results in voltage fluctuations and imbalance at consumer terminals. The application of such fluctuating voltages to operate centrifugal loads causes large variations in system performance. As a consequence, the incorporation of large safety factors have resulted in efficiency of pumping operations being less than 50% in most cases. However, small improvements in pump efficiency can lead to a significant reduction in energy consumption, and at the same time energy usage can be optimized. The operating point of a pump is obtained when the system curve intersects the pump curve. Variation in applied voltages leads to variation in the operating point, leading to inefficiency of system operation. This paper presents the impact of voltage variation and imbalance on the working performance of an induction motor-driven centrifugal pump system with an experimental study. Both overvoltage and undervoltage conditions along with phase imbalance were considered for analysis.

Original languageEnglish
Pages (from-to)562-569
Number of pages8
JournalIEEE Transactions on Industrial Electronics
Volume55
Issue number2
DOIs
Publication statusPublished - 02-2008

Fingerprint

Centrifugal pumps
Pumps
Electric potential
Safety factor
Induction motors
Energy utilization

All Science Journal Classification (ASJC) codes

  • Control and Systems Engineering
  • Computer Science Applications
  • Electrical and Electronic Engineering

Cite this

@article{27df61ec89aa497988d40b2d94c594e3,
title = "Performance analysis of centrifugal pumps subjected to voltage variation and unbalance",
abstract = "Frequent variation of single-phase loads on power system networks results in voltage fluctuations and imbalance at consumer terminals. The application of such fluctuating voltages to operate centrifugal loads causes large variations in system performance. As a consequence, the incorporation of large safety factors have resulted in efficiency of pumping operations being less than 50{\%} in most cases. However, small improvements in pump efficiency can lead to a significant reduction in energy consumption, and at the same time energy usage can be optimized. The operating point of a pump is obtained when the system curve intersects the pump curve. Variation in applied voltages leads to variation in the operating point, leading to inefficiency of system operation. This paper presents the impact of voltage variation and imbalance on the working performance of an induction motor-driven centrifugal pump system with an experimental study. Both overvoltage and undervoltage conditions along with phase imbalance were considered for analysis.",
author = "Kini, {P. Giridhar} and Bansal, {Ramesh C.} and Aithal, {R. S.}",
year = "2008",
month = "2",
doi = "10.1109/TIE.2007.911947",
language = "English",
volume = "55",
pages = "562--569",
journal = "IEEE Transactions on Industrial Electronics",
issn = "0278-0046",
publisher = "IEEE Industrial Electronics Society",
number = "2",

}

Performance analysis of centrifugal pumps subjected to voltage variation and unbalance. / Kini, P. Giridhar; Bansal, Ramesh C.; Aithal, R. S.

In: IEEE Transactions on Industrial Electronics, Vol. 55, No. 2, 02.2008, p. 562-569.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Performance analysis of centrifugal pumps subjected to voltage variation and unbalance

AU - Kini, P. Giridhar

AU - Bansal, Ramesh C.

AU - Aithal, R. S.

PY - 2008/2

Y1 - 2008/2

N2 - Frequent variation of single-phase loads on power system networks results in voltage fluctuations and imbalance at consumer terminals. The application of such fluctuating voltages to operate centrifugal loads causes large variations in system performance. As a consequence, the incorporation of large safety factors have resulted in efficiency of pumping operations being less than 50% in most cases. However, small improvements in pump efficiency can lead to a significant reduction in energy consumption, and at the same time energy usage can be optimized. The operating point of a pump is obtained when the system curve intersects the pump curve. Variation in applied voltages leads to variation in the operating point, leading to inefficiency of system operation. This paper presents the impact of voltage variation and imbalance on the working performance of an induction motor-driven centrifugal pump system with an experimental study. Both overvoltage and undervoltage conditions along with phase imbalance were considered for analysis.

AB - Frequent variation of single-phase loads on power system networks results in voltage fluctuations and imbalance at consumer terminals. The application of such fluctuating voltages to operate centrifugal loads causes large variations in system performance. As a consequence, the incorporation of large safety factors have resulted in efficiency of pumping operations being less than 50% in most cases. However, small improvements in pump efficiency can lead to a significant reduction in energy consumption, and at the same time energy usage can be optimized. The operating point of a pump is obtained when the system curve intersects the pump curve. Variation in applied voltages leads to variation in the operating point, leading to inefficiency of system operation. This paper presents the impact of voltage variation and imbalance on the working performance of an induction motor-driven centrifugal pump system with an experimental study. Both overvoltage and undervoltage conditions along with phase imbalance were considered for analysis.

UR - http://www.scopus.com/inward/record.url?scp=40449112594&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=40449112594&partnerID=8YFLogxK

U2 - 10.1109/TIE.2007.911947

DO - 10.1109/TIE.2007.911947

M3 - Article

VL - 55

SP - 562

EP - 569

JO - IEEE Transactions on Industrial Electronics

JF - IEEE Transactions on Industrial Electronics

SN - 0278-0046

IS - 2

ER -