Reliable transmission and storage of medical images with patient information using error control codes

Jagadish Nayak, P. S. Bhat, M. S. Kumar, U. Rajendra Acharya

Research output: Chapter in Book/Report/Conference proceedingConference contribution

12 Citations (Scopus)

Abstract

A new method for compact storage and transmission of medical Images with concealed patient Information in noisy environment if evinced. Digital Watermarking is the technique adapted here for interleaving patient Information with medical images. The patient information, which comprises of text data and signal graph, is encrypted to prevent unauthorized access of data. The latest encryption algorithm (Rijndael) is used for encrypting the text information. Signal graphs (ECG, EEG EMG etc.) are compressed using DPCM technique. To enhance the robustness of the embedded information, the patient Information Is coded by Error Correcting Codes (ECC) Reed Solomon (RS) codes. The noisy scenario Is simulated by adding salt and pepper (S&P) noise to the embedded Image. For different Signal to Noise Ratio (SNR) of the image, Bit Error Rate (BER) and Number of Character Altered (NOCA) for text data and percentage distortion (PDIST) for the signal graph is evaluated. It Is elicited that coded systems can perform better than the uncoded systems.

Original languageEnglish
Title of host publicationProceedings of the IEEE INDICON 2004 - 1st India Annual Conference
Pages147-150
Number of pages4
Publication statusPublished - 2004
EventIEEE INDICON 2004 - 1st India Annual Conference - Kharagpur, India
Duration: 20-12-200422-12-2004

Conference

ConferenceIEEE INDICON 2004 - 1st India Annual Conference
CountryIndia
CityKharagpur
Period20-12-0422-12-04

Fingerprint

Reed-Solomon codes
Digital watermarking
Electroencephalography
Electrocardiography
Bit error rate
Cryptography
Signal to noise ratio
Salts

All Science Journal Classification (ASJC) codes

  • Engineering(all)

Cite this

Nayak, J., Bhat, P. S., Kumar, M. S., & Rajendra Acharya, U. (2004). Reliable transmission and storage of medical images with patient information using error control codes. In Proceedings of the IEEE INDICON 2004 - 1st India Annual Conference (pp. 147-150)
Nayak, Jagadish ; Bhat, P. S. ; Kumar, M. S. ; Rajendra Acharya, U. / Reliable transmission and storage of medical images with patient information using error control codes. Proceedings of the IEEE INDICON 2004 - 1st India Annual Conference. 2004. pp. 147-150
@inproceedings{838c1ef7f08f4d4eb849ded8db72d656,
title = "Reliable transmission and storage of medical images with patient information using error control codes",
abstract = "A new method for compact storage and transmission of medical Images with concealed patient Information in noisy environment if evinced. Digital Watermarking is the technique adapted here for interleaving patient Information with medical images. The patient information, which comprises of text data and signal graph, is encrypted to prevent unauthorized access of data. The latest encryption algorithm (Rijndael) is used for encrypting the text information. Signal graphs (ECG, EEG EMG etc.) are compressed using DPCM technique. To enhance the robustness of the embedded information, the patient Information Is coded by Error Correcting Codes (ECC) Reed Solomon (RS) codes. The noisy scenario Is simulated by adding salt and pepper (S&P) noise to the embedded Image. For different Signal to Noise Ratio (SNR) of the image, Bit Error Rate (BER) and Number of Character Altered (NOCA) for text data and percentage distortion (PDIST) for the signal graph is evaluated. It Is elicited that coded systems can perform better than the uncoded systems.",
author = "Jagadish Nayak and Bhat, {P. S.} and Kumar, {M. S.} and {Rajendra Acharya}, U.",
year = "2004",
language = "English",
isbn = "0780389093",
pages = "147--150",
booktitle = "Proceedings of the IEEE INDICON 2004 - 1st India Annual Conference",

}

Nayak, J, Bhat, PS, Kumar, MS & Rajendra Acharya, U 2004, Reliable transmission and storage of medical images with patient information using error control codes. in Proceedings of the IEEE INDICON 2004 - 1st India Annual Conference. pp. 147-150, IEEE INDICON 2004 - 1st India Annual Conference, Kharagpur, India, 20-12-04.

Reliable transmission and storage of medical images with patient information using error control codes. / Nayak, Jagadish; Bhat, P. S.; Kumar, M. S.; Rajendra Acharya, U.

Proceedings of the IEEE INDICON 2004 - 1st India Annual Conference. 2004. p. 147-150.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

TY - GEN

T1 - Reliable transmission and storage of medical images with patient information using error control codes

AU - Nayak, Jagadish

AU - Bhat, P. S.

AU - Kumar, M. S.

AU - Rajendra Acharya, U.

PY - 2004

Y1 - 2004

N2 - A new method for compact storage and transmission of medical Images with concealed patient Information in noisy environment if evinced. Digital Watermarking is the technique adapted here for interleaving patient Information with medical images. The patient information, which comprises of text data and signal graph, is encrypted to prevent unauthorized access of data. The latest encryption algorithm (Rijndael) is used for encrypting the text information. Signal graphs (ECG, EEG EMG etc.) are compressed using DPCM technique. To enhance the robustness of the embedded information, the patient Information Is coded by Error Correcting Codes (ECC) Reed Solomon (RS) codes. The noisy scenario Is simulated by adding salt and pepper (S&P) noise to the embedded Image. For different Signal to Noise Ratio (SNR) of the image, Bit Error Rate (BER) and Number of Character Altered (NOCA) for text data and percentage distortion (PDIST) for the signal graph is evaluated. It Is elicited that coded systems can perform better than the uncoded systems.

AB - A new method for compact storage and transmission of medical Images with concealed patient Information in noisy environment if evinced. Digital Watermarking is the technique adapted here for interleaving patient Information with medical images. The patient information, which comprises of text data and signal graph, is encrypted to prevent unauthorized access of data. The latest encryption algorithm (Rijndael) is used for encrypting the text information. Signal graphs (ECG, EEG EMG etc.) are compressed using DPCM technique. To enhance the robustness of the embedded information, the patient Information Is coded by Error Correcting Codes (ECC) Reed Solomon (RS) codes. The noisy scenario Is simulated by adding salt and pepper (S&P) noise to the embedded Image. For different Signal to Noise Ratio (SNR) of the image, Bit Error Rate (BER) and Number of Character Altered (NOCA) for text data and percentage distortion (PDIST) for the signal graph is evaluated. It Is elicited that coded systems can perform better than the uncoded systems.

UR - http://www.scopus.com/inward/record.url?scp=28444476669&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=28444476669&partnerID=8YFLogxK

M3 - Conference contribution

SN - 0780389093

SN - 9780780389090

SP - 147

EP - 150

BT - Proceedings of the IEEE INDICON 2004 - 1st India Annual Conference

ER -

Nayak J, Bhat PS, Kumar MS, Rajendra Acharya U. Reliable transmission and storage of medical images with patient information using error control codes. In Proceedings of the IEEE INDICON 2004 - 1st India Annual Conference. 2004. p. 147-150