Simultaneous estimation of paracetamol and domperidone in tablets by reverse phase HPLC method

A. Karthik, G. Subramanian, A. Ranjith Kumar, N. Udupa

Research output: Contribution to journalArticle

31 Citations (Scopus)

Abstract

A simple, fast, precise and accurate liquid chromatographic method was developed for the simultaneous estimation of paracetamol and domperidone in combined dosage forms. This combination is used for antiemetic and pain associated with gastrointestinal disorders. Drugs are chromatographed on a reverse phase Kromasil C18 column using a mobile phase, 20 mM phosphate buffer (pH 7.0±0.1) and acetonitrile in the ratio of 60:40%v/v. Diclofenac potassium was used as an internal standard. The retention time of paracetamol, domperidone, and diclofenac potassium was 2.94, 8.30, 5.67 min, respectively. The validation of the proposed method was also carried out. The method was found to be linear (r>0.99), precise (%RSD: 0.49% for paracetamol and 0.89% for domperidone), accurate (overall average recovery yields: paracetamol 99.1% and domperidone 98.36%) and selective. Due to its simplicity and accuracy the proposed method can be used for routine quality control analysis of these drugs in combined dosage form.

Original languageEnglish
Pages (from-to)142-144
Number of pages3
JournalIndian Journal of Pharmaceutical Sciences
Volume69
Issue number1
Publication statusPublished - 01-01-2007

Fingerprint

Domperidone
Acetaminophen
Tablets
High Pressure Liquid Chromatography
Diclofenac
Dosage Forms
Antiemetics
Quality Control
Pharmaceutical Preparations
Buffers
Phosphates
Pain

All Science Journal Classification (ASJC) codes

  • Pharmaceutical Science

Cite this

@article{3056997f307b49d188c29ee811827a8e,
title = "Simultaneous estimation of paracetamol and domperidone in tablets by reverse phase HPLC method",
abstract = "A simple, fast, precise and accurate liquid chromatographic method was developed for the simultaneous estimation of paracetamol and domperidone in combined dosage forms. This combination is used for antiemetic and pain associated with gastrointestinal disorders. Drugs are chromatographed on a reverse phase Kromasil C18 column using a mobile phase, 20 mM phosphate buffer (pH 7.0±0.1) and acetonitrile in the ratio of 60:40{\%}v/v. Diclofenac potassium was used as an internal standard. The retention time of paracetamol, domperidone, and diclofenac potassium was 2.94, 8.30, 5.67 min, respectively. The validation of the proposed method was also carried out. The method was found to be linear (r>0.99), precise ({\%}RSD: 0.49{\%} for paracetamol and 0.89{\%} for domperidone), accurate (overall average recovery yields: paracetamol 99.1{\%} and domperidone 98.36{\%}) and selective. Due to its simplicity and accuracy the proposed method can be used for routine quality control analysis of these drugs in combined dosage form.",
author = "A. Karthik and G. Subramanian and {Ranjith Kumar}, A. and N. Udupa",
year = "2007",
month = "1",
day = "1",
language = "English",
volume = "69",
pages = "142--144",
journal = "Indian Journal of Pharmaceutical Sciences",
issn = "0250-474X",
publisher = "Medknow Publications and Media Pvt. Ltd",
number = "1",

}

Simultaneous estimation of paracetamol and domperidone in tablets by reverse phase HPLC method. / Karthik, A.; Subramanian, G.; Ranjith Kumar, A.; Udupa, N.

In: Indian Journal of Pharmaceutical Sciences, Vol. 69, No. 1, 01.01.2007, p. 142-144.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Simultaneous estimation of paracetamol and domperidone in tablets by reverse phase HPLC method

AU - Karthik, A.

AU - Subramanian, G.

AU - Ranjith Kumar, A.

AU - Udupa, N.

PY - 2007/1/1

Y1 - 2007/1/1

N2 - A simple, fast, precise and accurate liquid chromatographic method was developed for the simultaneous estimation of paracetamol and domperidone in combined dosage forms. This combination is used for antiemetic and pain associated with gastrointestinal disorders. Drugs are chromatographed on a reverse phase Kromasil C18 column using a mobile phase, 20 mM phosphate buffer (pH 7.0±0.1) and acetonitrile in the ratio of 60:40%v/v. Diclofenac potassium was used as an internal standard. The retention time of paracetamol, domperidone, and diclofenac potassium was 2.94, 8.30, 5.67 min, respectively. The validation of the proposed method was also carried out. The method was found to be linear (r>0.99), precise (%RSD: 0.49% for paracetamol and 0.89% for domperidone), accurate (overall average recovery yields: paracetamol 99.1% and domperidone 98.36%) and selective. Due to its simplicity and accuracy the proposed method can be used for routine quality control analysis of these drugs in combined dosage form.

AB - A simple, fast, precise and accurate liquid chromatographic method was developed for the simultaneous estimation of paracetamol and domperidone in combined dosage forms. This combination is used for antiemetic and pain associated with gastrointestinal disorders. Drugs are chromatographed on a reverse phase Kromasil C18 column using a mobile phase, 20 mM phosphate buffer (pH 7.0±0.1) and acetonitrile in the ratio of 60:40%v/v. Diclofenac potassium was used as an internal standard. The retention time of paracetamol, domperidone, and diclofenac potassium was 2.94, 8.30, 5.67 min, respectively. The validation of the proposed method was also carried out. The method was found to be linear (r>0.99), precise (%RSD: 0.49% for paracetamol and 0.89% for domperidone), accurate (overall average recovery yields: paracetamol 99.1% and domperidone 98.36%) and selective. Due to its simplicity and accuracy the proposed method can be used for routine quality control analysis of these drugs in combined dosage form.

UR - http://www.scopus.com/inward/record.url?scp=34248358722&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=34248358722&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:34248358722

VL - 69

SP - 142

EP - 144

JO - Indian Journal of Pharmaceutical Sciences

JF - Indian Journal of Pharmaceutical Sciences

SN - 0250-474X

IS - 1

ER -