Studies on development of soft robotic bending actuator using natural rubber

D. Deepak, Muhammad Ameen, Rohit Jagan, Kashish Kumar

Research output: Contribution to journalArticle

Abstract

Objectives: This article investigates the usage of natural rubber in raw form as an alternative to commercial elastomeric for manufacturing the soft robotic actuator. Methods: Soft actuator is fabricated with pure latex as well as with formic acid as additive. The mold surface was coated with releasing agent and the latex is carefully poured into the mold. Curing was made at room temperature for 2 days and post curing is done at 80 °C for two hours. Findings: The actuator made using natural latex without acid exhibited higher shrinkage. Whereas, the actuator treated with formic acid confirms the dimensional stability and comparatively lesser pores. Hence the natural latex with suitable additives can be used in the manufacture of soft actuators for robots. However, there is need of further investigation for establishing optimum combinations of the additives with natural rubber to obtain the desired properties in the actuator. Application: The developments in the proposed field of soft actuator reduce the cost of end effectors which find applications in medical as well as in engineering domain.

Original languageEnglish
Article number94660
JournalIndian Journal of Science and Technology
Volume9
Issue number42
DOIs
Publication statusPublished - 01-01-2016

Fingerprint

Rubber
Robotics
Actuators
Latexes
Formic acid
Curing
Dimensional stability
End effectors
Robots
Acids
Costs
Temperature

All Science Journal Classification (ASJC) codes

  • General

Cite this

Deepak, D. ; Ameen, Muhammad ; Jagan, Rohit ; Kumar, Kashish. / Studies on development of soft robotic bending actuator using natural rubber. In: Indian Journal of Science and Technology. 2016 ; Vol. 9, No. 42.
@article{86d77ed4a25a4cd5a3683b4c8f2a447d,
title = "Studies on development of soft robotic bending actuator using natural rubber",
abstract = "Objectives: This article investigates the usage of natural rubber in raw form as an alternative to commercial elastomeric for manufacturing the soft robotic actuator. Methods: Soft actuator is fabricated with pure latex as well as with formic acid as additive. The mold surface was coated with releasing agent and the latex is carefully poured into the mold. Curing was made at room temperature for 2 days and post curing is done at 80 °C for two hours. Findings: The actuator made using natural latex without acid exhibited higher shrinkage. Whereas, the actuator treated with formic acid confirms the dimensional stability and comparatively lesser pores. Hence the natural latex with suitable additives can be used in the manufacture of soft actuators for robots. However, there is need of further investigation for establishing optimum combinations of the additives with natural rubber to obtain the desired properties in the actuator. Application: The developments in the proposed field of soft actuator reduce the cost of end effectors which find applications in medical as well as in engineering domain.",
author = "D. Deepak and Muhammad Ameen and Rohit Jagan and Kashish Kumar",
year = "2016",
month = "1",
day = "1",
doi = "10.17485/ijst/2016/v9i42/94660",
language = "English",
volume = "9",
journal = "Indian Journal of Science and Technology",
issn = "0974-6846",
publisher = "Indian Society for Education and Environment",
number = "42",

}

Studies on development of soft robotic bending actuator using natural rubber. / Deepak, D.; Ameen, Muhammad; Jagan, Rohit; Kumar, Kashish.

In: Indian Journal of Science and Technology, Vol. 9, No. 42, 94660, 01.01.2016.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Studies on development of soft robotic bending actuator using natural rubber

AU - Deepak, D.

AU - Ameen, Muhammad

AU - Jagan, Rohit

AU - Kumar, Kashish

PY - 2016/1/1

Y1 - 2016/1/1

N2 - Objectives: This article investigates the usage of natural rubber in raw form as an alternative to commercial elastomeric for manufacturing the soft robotic actuator. Methods: Soft actuator is fabricated with pure latex as well as with formic acid as additive. The mold surface was coated with releasing agent and the latex is carefully poured into the mold. Curing was made at room temperature for 2 days and post curing is done at 80 °C for two hours. Findings: The actuator made using natural latex without acid exhibited higher shrinkage. Whereas, the actuator treated with formic acid confirms the dimensional stability and comparatively lesser pores. Hence the natural latex with suitable additives can be used in the manufacture of soft actuators for robots. However, there is need of further investigation for establishing optimum combinations of the additives with natural rubber to obtain the desired properties in the actuator. Application: The developments in the proposed field of soft actuator reduce the cost of end effectors which find applications in medical as well as in engineering domain.

AB - Objectives: This article investigates the usage of natural rubber in raw form as an alternative to commercial elastomeric for manufacturing the soft robotic actuator. Methods: Soft actuator is fabricated with pure latex as well as with formic acid as additive. The mold surface was coated with releasing agent and the latex is carefully poured into the mold. Curing was made at room temperature for 2 days and post curing is done at 80 °C for two hours. Findings: The actuator made using natural latex without acid exhibited higher shrinkage. Whereas, the actuator treated with formic acid confirms the dimensional stability and comparatively lesser pores. Hence the natural latex with suitable additives can be used in the manufacture of soft actuators for robots. However, there is need of further investigation for establishing optimum combinations of the additives with natural rubber to obtain the desired properties in the actuator. Application: The developments in the proposed field of soft actuator reduce the cost of end effectors which find applications in medical as well as in engineering domain.

UR - http://www.scopus.com/inward/record.url?scp=84996963918&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84996963918&partnerID=8YFLogxK

U2 - 10.17485/ijst/2016/v9i42/94660

DO - 10.17485/ijst/2016/v9i42/94660

M3 - Article

VL - 9

JO - Indian Journal of Science and Technology

JF - Indian Journal of Science and Technology

SN - 0974-6846

IS - 42

M1 - 94660