Towards continuous monitoring of pulse rate in neonatal intensive care unit with a webcam

Lalit K. Mestha, Survi Kyal, Beilei Xu, Leslie E.dward Lewis, Vijay Kumar

Research output: Contribution to journalArticle

32 Citations (Scopus)

Abstract

We describe a novel method to monitor pulse rate (PR) on a continuous basis of patients in a neonatal intensive care unit (NICU) using videos taken from a high definition (HD) webcam. We describe algorithms that determine PR from videoplethysmographic (VPG) signals extracted from multiple regions of interest (ROI) simultaneously available within the field of view of the camera where cardiac signal is registered. We detect motion from video images and compensate for motion artifacts from each ROI. Preliminary clinical results are presented on 8 neonates each with 30 minutes of uninterrupted video. Comparisons to hospital equipment indicate that the proposed technology can meet medical industry standards and give improved patient comfort and ease of use for practitioners when instrumented with proper hardware.

Fingerprint

Intensive care units
Neonatal Intensive Care Units
Heart Rate
Cameras
Hospital Equipment and Supplies
Hardware
Monitoring
Artifacts
Industry
Newborn Infant
Technology
Patient Comfort

All Science Journal Classification (ASJC) codes

  • Signal Processing
  • Biomedical Engineering
  • Computer Vision and Pattern Recognition
  • Health Informatics

Cite this

@article{6edd28bc410647ee82ae89cfa47d33d7,
title = "Towards continuous monitoring of pulse rate in neonatal intensive care unit with a webcam",
abstract = "We describe a novel method to monitor pulse rate (PR) on a continuous basis of patients in a neonatal intensive care unit (NICU) using videos taken from a high definition (HD) webcam. We describe algorithms that determine PR from videoplethysmographic (VPG) signals extracted from multiple regions of interest (ROI) simultaneously available within the field of view of the camera where cardiac signal is registered. We detect motion from video images and compensate for motion artifacts from each ROI. Preliminary clinical results are presented on 8 neonates each with 30 minutes of uninterrupted video. Comparisons to hospital equipment indicate that the proposed technology can meet medical industry standards and give improved patient comfort and ease of use for practitioners when instrumented with proper hardware.",
author = "Mestha, {Lalit K.} and Survi Kyal and Beilei Xu and Lewis, {Leslie E.dward} and Vijay Kumar",
year = "2014",
month = "1",
day = "1",
doi = "10.1109/EMBC.2014.6944455",
language = "English",
volume = "2014",
pages = "3817--3820",
journal = "Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings",
issn = "1557-170X",
publisher = "Institute of Electrical and Electronics Engineers Inc.",

}

TY - JOUR

T1 - Towards continuous monitoring of pulse rate in neonatal intensive care unit with a webcam

AU - Mestha, Lalit K.

AU - Kyal, Survi

AU - Xu, Beilei

AU - Lewis, Leslie E.dward

AU - Kumar, Vijay

PY - 2014/1/1

Y1 - 2014/1/1

N2 - We describe a novel method to monitor pulse rate (PR) on a continuous basis of patients in a neonatal intensive care unit (NICU) using videos taken from a high definition (HD) webcam. We describe algorithms that determine PR from videoplethysmographic (VPG) signals extracted from multiple regions of interest (ROI) simultaneously available within the field of view of the camera where cardiac signal is registered. We detect motion from video images and compensate for motion artifacts from each ROI. Preliminary clinical results are presented on 8 neonates each with 30 minutes of uninterrupted video. Comparisons to hospital equipment indicate that the proposed technology can meet medical industry standards and give improved patient comfort and ease of use for practitioners when instrumented with proper hardware.

AB - We describe a novel method to monitor pulse rate (PR) on a continuous basis of patients in a neonatal intensive care unit (NICU) using videos taken from a high definition (HD) webcam. We describe algorithms that determine PR from videoplethysmographic (VPG) signals extracted from multiple regions of interest (ROI) simultaneously available within the field of view of the camera where cardiac signal is registered. We detect motion from video images and compensate for motion artifacts from each ROI. Preliminary clinical results are presented on 8 neonates each with 30 minutes of uninterrupted video. Comparisons to hospital equipment indicate that the proposed technology can meet medical industry standards and give improved patient comfort and ease of use for practitioners when instrumented with proper hardware.

UR - http://www.scopus.com/inward/record.url?scp=84946734618&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84946734618&partnerID=8YFLogxK

U2 - 10.1109/EMBC.2014.6944455

DO - 10.1109/EMBC.2014.6944455

M3 - Article

VL - 2014

SP - 3817

EP - 3820

JO - Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings

JF - Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings

SN - 1557-170X